4. PROGRAMMING OPERATIONS

EO1-11149

4.17 %+ and %- Preset Rate Setting (Submode 36)

4.17 %+ and %- Preset Rate Setting (Submode 36)

A Preset Rate can be set on each of the [%+] and [%-]keys, one independent rate for each key. Once a rate is preset, the % key will simply be depressed without a prior rate entry to activate the preset rate. If a rate is entered prior to the depression of the key, the entered rate (manual rate) will be activated instead.

CONDITION

Anytime outside a sale

OPERATION

Control Lock: SET

36 [#/NS] Key Selection[#/NS]

01 or 02

(01: [%+] key

02:[%-] key)

Preset Rate [AT/TL]

0.00 to 99.99%

(Use the [.] key when a decimal point is contained in the rate.)

Tax Status 1 Tax Status 2 [AT/TL]

2 digits (Enter the codes in numeric values.) (Refer to Tax Status Tables below.)

[#/NS] To complete this programming operation.

Tax Status 1 Table

 

 

 

 

 

 

 

:

Default

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

 

 

5

6

7

Tax 1 taxable

 

 

O

 

O

 

 

 

O

 

O

Tax 2 taxable

 

 

 

O

O

 

 

 

 

O

O

Tax 3 taxable

 

 

 

 

 

O

 

O

O

O

Tax Status 2 Table

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

 

 

5

6

7

Tax 4 taxable

 

 

O

 

O

 

 

 

O

 

O

Reserved

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

Example) To program the following rate to each key.

 

 

 

 

 

 

[%+] key

 

 

 

 

 

 

 

 

 

 

 

Rate:

5.00%

 

 

 

 

 

 

 

 

 

 

Tax Status:

Non-taxable

 

 

 

 

 

 

 

 

 

[%-] key

 

 

 

 

 

 

 

 

 

 

 

Rate:

10.00%

 

 

 

 

 

 

 

 

 

 

Tax Status:

Non-taxable

 

 

 

 

 

 

 

 

 

Key Operation: Control Lock: SET, Enter 36 and depress the [#/NS] key.

[0] [1] [#/NS]

([%+] key)

[5][.] [0] [0] [AT/TL] (Percent Charge Rate)

[0][0] [AT/TL] (Tax Status (Non-taxable))

[0] [2] [#/NS]

([%-]key)

[1] [0] [.] [0]

[0]

[AT/TL]

(Percent Discount Rate)

[0]

[0]

[AT/TL]

(Tax Status (Non-taxable))

 

 

[#/NS]

(To complete this submode.)