4. PROGRAMMING OPERATIONS |
4.23 Tare Table Setting (Submode 56)
4.23 Tare Table Setting (Submode 56)
In 4.7 PLU Table Programming (Submode 4), some of
CONDITION | Anytime outside a sale |
OPERATION | Control Lock: SET |
Repeat for another table.
56 [#/NS] Tare Table No. [#/NS] Tare Weight [AT/TL]
1 digit (1 to 9) | X to 999X (gram) or 0 to 999 (LB) | |||
|
| (Unit: 1/100 LB or gram | ||
|
| Example: Enter 13 for 0.13 LB.) | ||
NOTE: In the lowest digit of the Tare Weight (gram), only the value “0” or “5” can be set. | ||||
Example) To set Tare Table No. 1 with Tare Weight 0.13 LB: |
|
| 35* | |
Key Operation: Control Lock: SET, Enter 56 and depress the [#/NS] key. |
| |||
| ||||
[1] [#/NS] | (Tare Table No. 1) |
|
| |
[1] [3] [AT/TL] | (Tare Weight) |
|
| |
[#/NS] | (To complete this submode.) |
| ||
|
|
|
|
|
[#/NS]
70
4.24 General Unit Weight Setting (Submode 57)
General Unit Weight can be set here so that the Unit Weight may be effective to scale items entered through departments or PLUs without any individual Unit Weight designation.
CONDITION | Anytime outside a sale |
OPERATION | Control Lock: SET |
57 [#/NS] General Unit Weight Code [AT/TL]
1 to 11
(Refer to General Unit Weight Code Table below.)
[#/NS]
General Unit Weight Code Table
Code | LB unit | Kg unit |
1 | 1 LB | 1 Kg |
2 | 2 LB | 2 Kg |
3 | 3 LB | 3 Kg |
4 | 4 LB | 4 Kg |
5 | 5 LB | 5 Kg |
6 | 6 LB | 6 Kg |
7 | 7 LB | 7 Kg |
8 | 8 LB | 8 Kg |
9 | 9 LB | 9 Kg |
10 | 1/2 LB | 100 g |
11 | 1/4 LB |
Example) To set General Unit Weight Code 2:
Key Operation:
Control Lock: SET,
Enter 57 and depress the [#/NS] key.
[2][AT/TL]
[#/NS]
35* 70