4. PROGRAMMING OPERATIONS |
4.12 PLU
4.12 PLU Preset-Code Key Setting (Submode 27)
To program keys on the ECR Keyboard as PLU
CONDITION | Anytime outside a sale |
OPERATION | Control Lock: SET |
Repeat for other keys.
27 [#/NS] PLU Code
Max. 14 digits
(Enter through Numeric Keys on the ECR Keyboard.
See NOTE 2 below.)
[KEY]
[#/NS]
Depress the required key on the ECR Keyboard. (See NOTE 3 below.)
NOTES: 1. | If PLU code entry is skipped and a [KEY] is simply depressed in the above sequence, pre- |
| programmed PLU code of the KEY is displayed. |
2. | If “0” is entered as PLU code in the above sequence, the KEY is reset. |
3. | The [KEY] in the above sequence should be set beforehand. For details, please contact |
| your TOSHIBA TEC representative. |
Example) To program the following PLU Codes to required KEYs on the ECR Keyboard. |
| ||||||||||||||||||||
|
|
| Key Operation: | Control Lock: SET |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| Enter 27, depress the [#/NS] key. |
|
|
| ||||||||||
|
|
|
| 01000000010101 [required key] [#/NS] |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| #/NS |
| RF | JF |
|
|
|
|
|
|
|
|
|
|
| |||
| 0 | 1 | 2 | 3 |
| 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| 11 | 12 |
| |||||
|
|
|
|
|
| ||||||||||||||||
|
|
|
| C |
| X/TIME |
|
|
|
|
|
|
|
|
|
|
| ||||
| 13 | 14 | 15 | 16 |
| 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 |
| 26 | 27 |
| |||
|
|
|
| 35* |
| ||||||||||||||||
|
|
|
| 7 |
| 8 | 9 |
|
|
|
|
|
|
|
|
|
|
|
| ||
| 28 | 29 | 30 | 31 |
| 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 |
| 41 | 42 |
|
| ||
|
|
|
| 4 |
| 5 | 6 |
|
|
|
|
|
|
|
|
|
|
|
| ||
| 43 | 44 | 45 | 46 |
| 47 | 48 | 49 | 50 | 51 | 52 | 53 | 54 | 55 |
| 56 | 57 | Map Code | 70 | ||
|
|
|
| 1 |
| 2 | 3 |
|
|
|
|
|
|
|
|
|
| ||||
| 58 | 59 | 60 | 61 |
| 62 | 63 | 64 | 65 | 66 | 67 | 68 | 69 | 70 |
| 71 | 72 |
|
|
|
|
|
|
|
| 0 |
| 00 | . |
| ST | AT/TL |
|
|
|
|
|
|
|
|
|
| |
| 73 | 74 | 75 | 76 |
| 77 | 78 | 79 | 80 | 81 | 82 | 83 | 84 | 85 |
| 86 | 87 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
29 [#/NS] |
|
| PLU Group Code [#/NS] |
| Character entry [AT/TL] |
|
| [#/NS] |
|
|
|
|
| ||||
|
|
|
|
| ||||
|
|
| 2 digits (01 to 99) |
| Max. 18 characters |
|
|
|
|
|
|
|
| (See NOTE below.) |
|
|
|
NOTE: Entering 2 digits of numeric code provides an alphanumeric character of PLU Group Name. Therefore, odd number of numeric digit entry will cause an error. When less than 36 digits of numeric data are entered, this ECR uses space code entry. If a PLU Group Name includes spaces at the beginning, entering space code is required at the beginning of data entry. For the PLU Group Name, up to 18