9. REGISTERING PROCEDURE AND PRINT FORMAT |
9.16 Mix & Match (M & M) Function of
Entry Contents | Key Operation | Sale Amount (Calculation Process) | |
(within one sale) |
|
|
|
1 x PLU No. 1 | 1 [SPLIT PRICE] 1 [PLU] | $0.40 | (Preset Individual Item Price) |
1 x PLU No. 2 | 1 [SPLIT PRICE] 2 [PLU] | $0.40 | (Preset Individual Item Price) |
1 x PLU No. 1 | 1 [SPLIT PRICE] 1 [PLU] | $0.40 | ($1.00 - $0.80) |
|
|
|
|
| Sale Total | $1.20 |
|
NOTES:
1.Calculation methods with/without M & M function
(1)Without M & M function,
B = The remainder of (Entry of Quantity) / (Whole Package Quantity)
(Sale Amount) = (A x Whole Package Price) + (B x Preset Individual Item Price)
(2)Without M & M function,
B = The remainder of (Entry of Quantity) / (Whole Package Quantity)
(Sale Amount) = (A x Whole Package Price) + (B x (Whole Package Price / Whole Package Quantity))
(3)With M & M function,
C = The quotient of (Accumulated entry of quantity) / (Whole Package Quantity) D = The remainder of (Accumulated entry of quantity) / (Whole Package Quantity)
(Sale Amount) = (C x Whole Package Price) + (D x Preset Individual Item Price) - (Previous Sale Amount)
(4)With M & M function,
C = The quotient of (Accumulated entry of quantity) / (Whole Package Quantity) D = The remainder of (Accumulated entry of quantity) / (Whole Package Quantity)
(Sale Amount) = (C x Whole Package Price) + (D x (Whole Package Price / Whole Package Quantity))
-(Previous Sale Amount)
(5)When Whole Package Price is not programmed
When the Whole Package Price is entered through the keys, the Sale Total will be calculated same as methods (2) and (4) above.
2.The quantity can be entered with up to
3.Without entry of quantity, a PLU will be entered with Whole Package Price.
4.With “Cashier interruption is allowed” setting, M & M function is unavailable.
5.With M & M function, up to 99 items can be purchased. When one of 99 sales items is returned or corrected, one item can be entered.
6.Whole Package Price can be entered in the range of 1 to 999999999.
7.Without M & M group setting, the M & M function will be performed for each PLU.