7. CIRCUIT CONFIGURATION AND CONTROL SPECIFICATIONS

7-1. Outdoor Unit Control

7-1-1. Print Circuit Board, MCC-1596 (Compressor IPDU)

CN851 (Red)

CN07 (Blue), CN08 (Blue)

CN101 (White)

Connector for MCC-1597 (CN505)

Terminal for reactor CH44

Connector for MCC-1597 (CN502)

CN03 (Black)

Terminal for power relay

CN201 (Red), CN202 (White), CN203 (Black) Compressor output terminal

F02

Electric circuit protective fuse (500V, 31.5A)

CN02 (White)

Terminal for MCC-1600 (CN17)

F01

Electric circuit protective fuse (500V, 31.5A)

CN01 (Red)

Terminal for power relay

CN04 (Red)

Terminal for PTC thermistor

CN09 (Yellow), CN10 (Yellow)

Terminal for reactor CH44

– 45 –

Page 45
Image 45
Toshiba RAV-SM2244AT8ZG-E, RAV-SM2804AT8ZG-E Circuit Configuration and Control Specifications, Outdoor Unit Control