Toshiba RAV-SM2244AT8ZG-E service manual 11Compressor 2. Attachment, Vacuuming, Refrigerant charge

Models: RAV-SM2244AT8Z-E RAV-SM2804AT7ZG RAV-SM2804AT7 RAV-SM2804AT7Z RAV-SM2244AT7 RAV-SM2804AT8-E RAV-SM2244AT7Z RAV-SM2244AT7ZG RAV-SM2804AT8Z-E RAV-SM2244AT8ZG-E RAV-SM2804AT8ZG-E

1 133
Download 133 pages 47.63 Kb
Page 122
Image 122
11Compressor 2. Attachment

No. Part name

Procedure

Remarks

11Compressor 2. Attachment

(continued)

1) Mount the compressor by reversing the procedure for removal.

CAUTION

The fixing torque for the hexagonal bolts fixing the compressor is 19.6N•m (200kgf•cm).

3.Vacuuming

1)Connect the vacuum pump to the charge port and the high-pressure check joint of the liquid pipe and the gas pipe valve and then operate the vacuum pump.

2)Carry out vacuuming until the vacuum low pressure gauge indicates 1 (mmHg).

CAUTION

Before vacuuming, open the pulse motor valve fully. If the pulse motor valve is closed, vacuuming may be impossible of the heat exchanger in the outdoor unit.

Forcible fully-opened method for the pulse motor valve

Turn on the breaker switch.

Short circuit CN300 on the interface board of the outdoor unit.

Turn off the breaker switch.

4.Refrigerant charge

1)Add a refrigerant amount determined by the pipe length from the charge port of the valve.

CAUTION

The water-proof sheet (rubber sheet) should be mounted so that water drops from the accumulator or the pipes do not come into contact with the terminal section of the compressor.

12Pulse motor 1. Detachment

valve (PMV)

1)

Carry out work of item 1. of Q and T above.

Accumulator

PMV unit

coil

2)

Rotate the coil while pulling upwardly and then

 

 

 

 

 

 

 

 

 

remove the coil from the pulse motor valve coil

 

 

 

 

 

main unit.

 

 

 

 

 

 

 

 

 

2. Attachment

1) Surely match the positioning projection of the coil with the concave part of PMV main unit and then fix it.

 

CAUTION

 

 

 

 

 

 

Mount the coils or the coil carefully so that they do

PMV coil

not make contact with the accumulator.

 

 

 

 

 

 

 

 

 

– 122 –

Page 122
Image 122
Toshiba RAV-SM2244AT8ZG-E 11Compressor 2. Attachment, Vacuuming, Refrigerant charge, 12Pulse motor 1. Detachment