SCANNER CONFIGURATION MANAGER

Bar Code Symbologies, continued

Code 32

zEnabled toggles the ability for the scanner to read Code 32 on or off. Default is “No”.

zCode ID is a user-definable identification letter for Code 32, which is referred to in the “Use Code ID” function on page 45.

Default is letter “T”.

zSend Leading Character toggles sending or not sending a leading (‘start bar code’) character.

Default is “Send”.

zSend Tailing Character toggles sending or not sending a tailing (‘stop bar code’) character.

Default is “Send”.

EAN 128

zEnabled toggles the ability for the scanner to read EAN 128 on or off.

Default is “No”.

zCode ID is a user-definable identification letter for EAN 128, which is referred to in the “Use Code ID” function on page 45.

Default is letter “None”.

zEnable Code ID determines whether or not to assign a Code ID. Default is “No”.

zField Separator is a user-definable character to insert between fields.

Default is “None”.

Code 128

zEnabled toggles the ability for the scanner to read Code 128 on or off.

Default is “No”.

zCode ID is a user-definable identification letter for Code 128, which is referred to in the “Use Code ID” function on page 45.

Default is letter “None”.

zMinimum Length defines the minimum length the user will accept for a valid bar code.

Default is “1”.

zMaximum Length defines the maximum length the user will accept for a valid bar code.

Default is “64”.

51