Unitech MS860 MSI / Plessey Code, Scanner Configuration Manager, Bar Code Symbologies, continued

Models: MS860

1 96
Download 96 pages 38.94 Kb
Page 54
Image 54
MSI / Plessey Code

SCANNER CONFIGURATION MANAGER

Bar Code Symbologies, continued

MSI / Plessey Code

zEnabled toggles the ability for the scanner to read MSI / Plessey Code on or off.

Default is “Yes”.

zMSI Code ID is a user-definable identification letter for MSI Code, which is referred to in the “Use Code ID” function on page 45. Default is letter “O”.

zPlessey Code ID is the same as MSI Code ID (above) but instead applicable to Plessey Code.

Default is letter “P”.

zSend Check Digit toggles whether or not to send a check digit. Default is “No Send”.

zCheck Digit Formula defines the formula to calculate the check digit. Options are:

Double Module 10 Module 11 Plus 10 Single Module 10

Default is “Double Module 10”.

zMinimum Length defines the minimum length the user will accept for a valid bar code.

Default is “10”.

zMaximum Length defines the maximum length the user will accept for a valid bar code.

Default is “64”.

Code 93

zEnabled toggles the ability for the scanner to read Code 93 on or off.

Default is “Yes”.

zCode ID is a user-definable identification letter for Code 93, which is referred to in the “Use Code ID” function on page 45.

Default is letter “L”.

zMinimum Length defines the minimum length the user will accept for a valid bar code.

Default is “1”.

zMaximum Length defines the maximum length the user will accept for a valid bar code.

Default is “48”.

MS860 WiFi Manual

52

Page 54
Image 54
Unitech MS860 manual MSI / Plessey Code, Scanner Configuration Manager, Bar Code Symbologies, continued