Unitech MS860 EAN-8, Delta Code, Scanner Configuration Manager, Bar Code Symbologies, continued

Models: MS860

1 96
Download 96 pages 38.94 Kb
Page 57
Image 57
EAN-8

SCANNER CONFIGURATION MANAGER

Bar Code Symbologies, continued

EAN-8

zEnabled toggles the ability for the scanner to read EAN-8 on or off. Default is “Yes”.

zCode ID is a user-definable identification letter for EAN-8, which is referred to in the “Use Code ID” function on page 45.

Default is letter “FF”.

zSend Leading Digit toggles sending or not sending a leading (‘start bar code’) digit.

Default is “Send”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.

Code 11

zEnabled toggles the ability for the scanner to read Code 11 on or off. Default is “Yes”.

zCode ID is a user-definable identification letter for Code 11, which is referred to in the “Use Code ID” function on page 45.

Default is letter “J”.

zSend Check Digit Number defines the check digit . Default is “Send”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.

zMinimum Length defines the minimum length the user will accept for a valid bar code.

Default is “3”.

zMaximum Length defines the maximum length the user will accept for a valid bar code.

Default is “48”.

Delta Code

zEnabled toggles the ability for the scanner to read Delta Code on or off. Default is “No”.

zCode ID is a user-definable identification letter for Delta Code, which is referred to in the “Use Code ID” function on page 45. Default is letter “D”.

zCalculate Check Digit toggles whether or not to calculate a check digit.

Default is “Yes”.

zSend Check Digit toggles sending or not sending a check digit. Default is “Send”.