Priority Lockout Mode (Factory default: “DISABLED”)
This mode is the opposite of “Whole House”. That is, when one is ENABLED, the other is DISABLED. When ENABLED, if Zone 1 selects a source, Zone 1 will maintain exclusive control over that source until Zone 1 either selects another source or is turned OFF. Zones
IR Routing (Factory default: “ENABLED”)
This mode allows selective control of multiple
Backlight Control (Factory default: 6 seconds)
This setting adjusts the duration that the Keypad LCD and Buttons will remain lit after a keypad button press. Backlighting is variable from ‘always off’ to ‘always on’ or set to time out after 1 to 10 seconds in one second increments. This setting will set the backlighting for ALL keypads in the system. IR codes generated by remote controls do not activate backlighting.
1.Click “ALWAYS ON” to backlight a zone’s keypad(s) for as long as the zone is ON. Backlight turns off when the zone is turned OFF. Useful in dark rooms.
2.Click “ALWAYS OFF” keypad(s) backlight will never turn on. Useful in rooms that are always brightly lit.
3.Click “TIMED” and use ‘Timed Backlight Control’ Pulldown Menu to set backlight duration from
Monitor Lockout Mode (Factory default: “DISABLED”)
This mode can only be used if ‘Priority Lockout’ is selected. Checking the corresponding boxes prevents sources from being monitored or controlled in specific zones. Example: If adult content is not to go to the children’s areas this can be set at the time of system installation.
1.Select “PRIORITY LOCKOUT MODE” The Monitor Lockout boxes will be activated.
2.By Zone, click in the box of any Source that is not to be monitored in that zone.
Dynamic Monitor Lockout (Factory default: “DISABLED”)
This mode allows monitor lockout ‘on the fly’. There may be times when a source is generating program material that can be made available to all zones/users. At other times this same source may be putting out material that is not suitable for some zones/users. When the “ADMINISTRATOR” box is checked for a given zone, for example, Zone 1, a special keypad command can block the audio and video for a given source from being monitored by Zones
1.Select “PRIORITY LOCKOUT MODE” The Monitor Lockout boxes will be activated.
2.Click the “ADMINISTRATOR” box for any zone that is to have ‘Dynamic Monitor Lockout’ ability.
3.After the project has been transferred to the MRC44 Controller, on a keypad in a zone with ‘Administrator’ control, simultaneously press the ”STATUS” and “SOURCE” buttons for the device to be ‘locked out’. If any zone has that same source selected, the audio will mute and the video will go blank. A message: “Monitor Locked” will appear on the keypad(s) in those zones.
4.To unlock, from the same zone with ‘Administrator’ control, simultaneously press ”STATUS” and “SOURCE” again. If any zone has that same source selected, the message “Monitor Unlocked” will appear, however, video and audio will not be routed to that zone until a source select button is pressed. A message: “Monitor Unlocked” will appear on the keypad(s) in those zones. The ‘Administrator’ zone will retain priority until that zone selects another source or turns OFF.
IR Output Intensity Settings
Emitter outputs 3, 4 and common have adjustable output levels to compensate for the varying IR sensitivities in different branded products. The Low setting is equivalent to the emitter out on a