ZyXEL Communications 128MH 7 below describes the call control parameters, Field, Description

Models: 128MH

1 185
Download 185 pages 26.46 Kb
Page 53
Image 53
Table 2-7 below describes the call control parameters.

Prestige 128MH PSTN Router/Hub

Table 2-7 below describes the call control parameters.

Table 2-7.

Advanced WAN Port Setup Call Control Parameters

 

 

 

 

 

Field

 

Description

Default

 

 

 

Dial Timeout (sec)

The Prestige will timeout if it can not set up an outgoing

[60] seconds

 

 

modem call within the timeout value.

 

 

 

 

 

Retry Count

 

How many times a busy or no-answer phone number is

[0] to disable the

 

 

retried before it is put on the blacklist.

blacklist control

 

 

 

Retry Interval (sec)

Elapsed time after a call fails before another call may be

 

 

 

retried. Applies before a phone number is blacklisted.

 

 

 

 

Drop Timeout (sec)

The Prestige will drop the DTR signal if it does not receive a

[20] seconds

 

 

positive confirmation of disconnect within the timeout period.

 

 

 

 

 

Call Back Delay

 

Elapsed time between dropping a callback request call and

[15] seconds

(sec)

 

dialing a callback call.

 

 

 

 

 

Hardware Installation & Initial Setup

2-23

Page 53
Image 53
ZyXEL Communications 128MH 7 below describes the call control parameters, Advanced WAN Port Setup Call Control Parameters