Level 1

Level 2

Level 3

Password Check

Yes

Yes

Yes

CPN Check OK

N/A

Call back

Prompts the

and S119.6=0

 

 

remote user

 

 

 

to enter call

 

 

 

back

 

 

 

number

CPN Check OK

N/A

Keep the

for calling

and S119.6=1

 

connection

back.

CPN unmatched

N/A

Disconnect

 

CPN not

N/A

Call back using

 

Available

 

the corresponding

 

 

 

pre-stored number

 

AT Commands

*G1 for

*G2 for Type 1

*G5 for

 

Type 1

*G4 for Type 2

Type 2

 

*G3 for

 

 

 

Type 2

 

 

Setting and Modifying Passwords

Up to 40 user passwords can be defined using the AT*Hn command, where “n” represents the index to the entry. Numbers between 0-39 are accepted.

The corresponding 40 call-back numbers are defined by

AT&Zn=xxx command, where “n” represents the index to the entry, and “xxx” represents the assigned call-back phone number. Any character (ASCII 0-127) can be used in the password table, the maximum password length is 8 characters for each entry.

Security functions are only accessible through AT commands in terminal mode. A supervisory password is required for adding or modifying entries. The default supervisor password is ZyXEL when the TA is shipped from the factory. This supervisory password is sent to the remote if Type 1 security is set at the remote end.

To modify the supervisor password, use AT*HS.

Security Functions 95

Page 107
Image 107
ZyXEL Communications omni series user manual Setting and Modifying Passwords