Output Parameter | Output Value Description |
Connect DTE Speed | Current |
Error Control Level | Error control protocol used for current |
| session. |
Protocol Link Speed | Current |
Octets Received | Number of data octets received from |
| remote. |
Octets Sent | Number of data octets sent to remote. |
Cause | Verbose disconnection reason for the last |
| session. |
Cause Value | Numerical disconnection reason for the last |
| session. |
HDLC FCS Error | Errors in frame (block) checksum (If there |
| were many FCS Errors, you may have |
| experienced problems on the line). |
HDLC Transmit | For TA's processor power measurement. |
| |
HDLC Receive | For TA's processor power measurement. |
|
Extended "AT&" Command Set
Command | Options | Function & Description | Ref. |
&Cn |
| Carrier Detect (CD) options | S21.4 |
| &C0 | CD always ON (See also S42.7) |
|
| &C1 * | CD tracks presence of carrier (See |
|
|
| also S38.3, S42.7) |
|
&Dn |
| Data Terminal Ready (DTR) options. | |
|
| (See also S25) |
|
| &D0 | Ignore DTR signal, assume DTR is |
|
|
| always ON. |
|
| &D1 | 108.1, DTR |
|
|
| causes dial of the default number. |
|
|
| (See also 'AT*Dn' and S48.4) |
|
| &D2 * | 108.2, Data Terminal Ready, DTR |
|
|
| OFF causes the TA to hang up. |
|
118 AT Command Set Reference