beginning of data capture. The resolution of this timing information is in 0.01 second intervals.

The following commands determine the kind of protocol data to be captured by the EPA:

AT Command

Description

ATCDn

 

CD0

Disable the capture of D-channel protocols.

CD1

Enable the capture of D-channel protocols

 

(default).

ATCBn

 

CB0

Disable the capture of B-channel protocols

 

(default).

CB1

Enable the capture of B-channel protocols.

ATCCn

 

CC0

Disable the capture of DTE-DCE interface

 

protocols(default).

CC1

Enable the capture of DTE-DCE interface

 

protocols.

The EPA starts to capture data when the command ATCT is issued. This capturing process will continue until the command ATC$ is issued. The EPA maintains 8 Kbytes RAM as a ring buffer. In case the buffer is full, the earliest data captured will be overwritten by the latest data.

Analyzing the Captured Data

To view the analyzed result, use the command ATC$. For your convenience, the relevant AT commands are summarized as follows:

Command

Description

ATCT

Clears buffer and starts the embedded protocol

 

analyzer. Captures data immediately and starts the

 

timer.

Diagnostics 105

Page 117