beginning of data capture. The resolution of this timing information is in 0.01 second intervals.
The following commands determine the kind of protocol data to be captured by the EPA:
AT Command | Description |
ATCDn |
|
CD0 | Disable the capture of |
CD1 | Enable the capture of |
| (default). |
ATCBn |
|
CB0 | Disable the capture of |
| (default). |
CB1 | Enable the capture of |
ATCCn |
|
CC0 | Disable the capture of |
| protocols(default). |
CC1 | Enable the capture of |
| protocols. |
The EPA starts to capture data when the command ATCT is issued. This capturing process will continue until the command ATC$ is issued. The EPA maintains 8 Kbytes RAM as a ring buffer. In case the buffer is full, the earliest data captured will be overwritten by the latest data.
Analyzing the Captured Data
To view the analyzed result, use the command ATC$. For your convenience, the relevant AT commands are summarized as follows:
Command | Description |
ATCT | Clears buffer and starts the embedded protocol |
| analyzer. Captures data immediately and starts the |
| timer. |
Diagnostics 105