ZyXEL Communications omni series user manual ATXn Result Code Option Table, ATV0 ATV1

Models: omni series

1 168
Download 168 pages 22.94 Kb
Page 157
Image 157

Command

bit

dec

hex

Function and description

Ref.

S127=

 

0-

0-

Sub-threshold for BOD in Kbps

JSn,+32

 

 

255

FF

unit

 

S128=

bit

dec

hex

For DTE port 2 only.

 

 

0

*0

0

Two POTS and one DTE port.

 

 

 

1

1

One POTS and two DTE ports

 

Bit - S-register bit number, 'b', used in 'ATSr.b=n' and 'ATSr.b=?'

dec - Decimal value, 'x', used in 'ATSn=x'

hex - Equivalent Hexadecimal value.

+nnn - Factory default when listed in 'Reference' column.

"ATXn" Result Code Option Table

The following table shows the different options available when setting the ATXn command. The default value for ‘n’ is 5 when the omni is shipped:

ATV0

ATV1

X0

X1

X2

X3

X4

X5

X6

X7

0

OK

V

V

V

V

V

V

V

V

1

CONNECT

V

V

V

V

V

@

$

#

2

RING

V

V

V

V

V

V

V

V

3

NO CARRIER

V

V

V

V

V

V

V

V

4

ERROR

V

V

V

V

V

V

V

V

5

CONNECT 1200

 

%

%

%

%

@

$

#

6

NO DIAL TONE

 

 

V

 

V

V

V

V

7

BUSY

 

 

 

V

V

V

V

V

8

NO ANSWER

 

 

 

V

V

V

V

V

9

RINGING*

 

 

 

V

V

V

V

V

10

CONNECT 2400

 

%

%

%

%

@

$

#

11

CONNECT 4800

 

%

%

%

%

@

$

#

12

CONNECT 9600

 

%

%

%

%

@

$

#

14

CONNECT 19200

 

%

%

%

%

@

$

#

15

CONNECT 7200

 

%

%

%

%

@

$

#

16

CONNECT 12000

 

%

%

%

%

@

$

#