ZyXEL Communications omni series user manual Ppp

Models: omni series

1 168
Download 168 pages 22.94 Kb
Page 156
Image 156

Command

bit

dec

hex

Function and description

Ref.

 

 

32

20

Treat the number assigned by

 

 

 

 

 

&ZI=n... as sub-address, and

 

 

 

 

 

match with the

 

 

 

 

 

called_party_subaddress for

 

 

 

 

 

inbound call routing

 

S120=

0

*0

0

Enable POTS port 1 call out.

 

 

 

1

1

Disable POTS port 1 call out.

 

 

1

*0

0

Enable POTS port 2 call out.

 

 

 

2

2

Disable POTS port 2 call out.

 

 

2

*0

0

Enable multi-answering while

 

 

 

 

 

TA MSN is not assigned.

 

 

 

4

4

Handle incoming calls

 

 

 

 

 

according to AT&Ln setting.

 

 

3

*0

0

If S120.2=1 is set and the

 

 

 

 

 

POTS port is busy, calls will be

 

 

 

 

 

routed to another POTS port.

 

 

 

8

8

If S120.2=1 is set and the

 

 

 

 

 

POTS port is busy, calls will be

 

 

 

 

 

rejected.

 

 

4

*0

0

Enable TA to accept global

 

 

 

 

 

calls for a/b adapter and ISDN

 

 

 

 

 

data.

 

 

 

16

10

Reject unmatched calls for a/b

 

 

 

 

 

adapter and ISDN data.

 

S124=

 

dec

hex

Empty IP packet interval for

+000

 

 

 

 

PPP

 

 

 

0-

0-

Units of 1 sec.

 

 

 

255

FF

 

 

S125=

bit

dec

hex

 

 

 

1-6

 

*0

Sub-persist time interval.

KSxn

 

7

0

*0

S125b1-6 is in Second unit.

KSSn

 

 

128

80

S125b1-6 is in Minute unit.

KSMn

S126=

 

0-

0-

Add-threshold for BOD in

JAn,+48

 

 

255

FF

Kbps unit

 