LINE COMMANDS

the next logon attempt. Use the silent-timecommand to set this interval.

This command applies to both the local console and Telnet connections.

Example

To set the password threshold to five attempts, enter this command:

Console(config-line)#password-thresh 5

Console(config-line)#

Related Commands

silent-time

silent-time

Use this command to set the amount of time the management console is inaccessible after the number of unsuccessful logon attempts exceeds the threshold set by the password-threshcommand. Use the no form to remove the silent time value.

Syntax

silent-time seconds no silent-time

seconds - The number of seconds to disable console response. (Range: 0-65535; 0: no silent-time)

Default Setting

The default value is no silent-time.

Command Mode

Line Configuration

Example

To set the silent time to 60 seconds, enter this command:

Console(config-line)#silent-time 60

Console(config-line)#