SMC Networks SMC7724M/VSW manual Show controllers efm status, 160

Models: SMC7724M/VSW

1 316
Download 316 pages 43.27 Kb
Page 296
Image 296

COMMAND LINE INTERFACE

Note: If an “LL” type profile is selected, the error rate due to noise in transmission, is increased, but the signal latency is decreased

Related Commands

show controllers efm interface-id actual show controllers efm interface-id admin

show controllers efm status

Use this command to display the VDSL link statistics and profile information on a specific VDSL port including link state, link duration, data rates, power levels, signal-to-noise ratio, and Reed-Solomon errors.

Syntax

show controllers efm status {link profile} [interface-id]

interface-id- ID of the VDSL port

link - Displays VDSL link parameters and status.

profile - Displays VDSL link parameters and status.

Default Setting

None

Command Mode

Privileged EXEC

Command Usage

SNR and Reed-Solomon error information display the quality of the VDSL link.

Using this command without specifying a VDSL port displays the status of all VDSL ports.

The SNR represents the upper limit of received signal to noise ratio that the switch will handle before disconnecting from the remote CPE.

The Reed-Solomon errors show the number of errors detected and corrected in the data being received on and transmitted from

3-160

Page 296
Image 296
SMC Networks SMC7724M/VSW manual Show controllers efm status, 160