SMC Networks SMC7724M/VSW manual Vdsl Port Link Status, 103

Models: SMC7724M/VSW

1 316
Download 316 pages 43.27 Kb
Page 131
Image 131

VDSL CONFIGURATION

VDSL Port Link Status

Fields and Attributes

Link – Shows the status of the VDSL link.

Link Fail Count – The number of times the switch has tried to re-establish the link with the CPE since the link went down.

SNR (dB) The signal-to-noise ratio of the switch.

Downstream Rate (Mbps) – The rate at which data is transmitted from the switch to the CPE.

Upstream Rate (Mbps) – The rate at which data is transmitted from the CPE to the switch.

Local Receiver Power (dBm/Hz) The power at which the signal from the CPE port is received on the switch VDSL port.

Remote Transmit Power (dBm/Hz) – The power at which the signal is transmitted from the CPE port to the switch.

PMD-SPhysical Media Dependent Flag for the VDSL chip.

Downstream Reed-Solomon Errors – The number of errors in the downstream data that have been corrected by the Reed-Solomon code.

Upstream Reed-Solomon Errors – The number of errors in the upstream data that have been corrected by the Reed-Solomon code.

Local/Remote Receive Interleave Depth – The interleave depth is a parameter that determines the degree of protection of the data signal against impulse noise provided by interleaving. The values of the interleave depth that can be set by the user are 0, 1, 2, 8, and 16; 16 specifies maximum protection. Local Receive Interleave Depth refers to protection provided on the signal received at on the VDSL switch port. Remote Receive Interleave Depth refers to protection provided on the signal received on the CPE port.

2-103