C
ONFIGURING
THE
S
WITCH
2-102
Downstream Rate – The rate at which data is transmitted from the
switch to the CPE.
Upstream Rate – The rate at which data is transmitted from the CPE
to the switch.
Interleave Depth – The interleave depth is a parameter that
determines the degree of protection of the data sign al against impulse
noise provided by interleaving. The default value is 0. This means that
the interleaver is disabled. The values of the inte rleave depth that can
be set by the user are 0, 1, 2, 8, and 16; 16 specifies maximum
protection.
Web Inte rfac e
Click VDSL/VDSL Profile User Specified.
Command Line Interface
The following example shows user-profile 1 configured to a downstream
rate of 15Mbps, an upstream rate of 5 Mbps, and an interleave depth of 2.
Console(config)#efm define user-profile 1 15 5 2 3-150
Console(config)#