Briggs & Stratton 30239 owner manual Dont Overload Generator, Capacity, Power Management, Example

Page 13

2000W Generator

DON'T OVERLOAD GENERATOR

3.Permit the generator output to stabilize (engine runs smoothly and attached device operates properly.

4.Plug in and turn on the next load.

5.Again, permit the generator to stabilize.

Capacity

You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:

1.Select the items you will power at the same time.

2.Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Figure 12.

3.Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Example:

Tool or Appliance

Rated (Running)

Additional Surge

Watts

(Starting) Watts

 

 

 

 

Refrigerator

800

1600

 

 

 

Deep Freezer

500

500

 

 

 

Television

500

-

 

 

 

Light (75 Watts)

75

-

 

 

 

 

1875 Total Running

1600 Highest Surge

 

Watts

Watts

 

 

 

Total Rated (Running) Watts

= 1875

Highest Additional Surge Watts

= 1600

Total Generator Output Required

= 3475

Power Management

To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting it's engine. The correct and safe way to manage generator power is to sequentially add loads as follows:

1.With nothing connected to the generator, start the engine as described in this manual.

2.Plug in and turn on the first load, preferably the largest load you have.

6.Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.

Figure 12 - Wattage Reference Chart

 

Rated*

Additional

 

Surge

Tool or Appliance

(Running)

(Starting)

 

Watts

 

Watts

 

 

Essentials

 

 

Light Bulb - 75 watt

75

-

Deep Freezer

500

500

Sump Pump

800

1200

Refrigerator/Freezer - 18 Cu. Ft.

800

1600

Water Well Pump - 1/3 HP

1000

2000

Heating/Cooling

 

 

Window Fan

300

600

Furnace Fan Blower - 1/2 HP

800

1300

Kitchen

 

 

Microwave Oven - 1000 Watt

1000

-

Coffee Maker

1500

-

Electric Stove - Single Element

1500

-

Hot Plate

2500

-

Family Room

 

 

Stereo Receiver

450

-

Television - 27”

500

-

Personal Computer w/17” monitor

800

-

Other

 

 

AM/FM Clock Radio

300

-

Electric Water Heater - 40 Gallon

4000

-

Quartz Halogen Work Light

1000

-

Airless Sprayer - 1/3 HP

600

1200

Reciprocating Saw

960

960

Electric Drill - 1/2 HP

1000

1000

Circular Saw - 7 1/4”

1500

1500

Miter Saw - 10”

1800

1800

Table Saw/Radial Arm Saw - 10”

2000

2000

Air Compressor - 1-1/2 HP

2500

2500

 

 

 

*Wattages listed are approximate only. Check tool or appliance for actual wattage.

13

Image 13
Contents 030239 2000W Safety Rules Table of ContentsEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorEngine ON/OFF Switch Engine ON/OFF Switch Used to stop a running engineKnow Your Generator Before Starting Engine AssemblyAdd Fuel When Adding FuelTo Add Engine Oil Connecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationGenerator OperatingStarting the Engine Connecting Electrical Loads Charging a BatteryStopping the Engine Oil Alert SystemReceptacles Volt DC Accessory JackCold Weather Operation Volt AC, 15 Amp ReceptaclePermanent Cold Weather Shelter Remove shelter when temperatures are above 40F 4CDont Overload Generator Power ManagementCapacity ExamplePower Ratings Product SpecificationsGenerator Specifications Engine SpecificationsGenerator Cleaning Generalgenerator Recommendations MaintenanceEmission Control Clean/Replace Spark Plug Engine MaintenanceClean area around oil drain plug Figure Checking Oil LevelClean Spark Arrester Screen Service Air CleanerTo clean or replace air cleaner Air Cooling SystemLong Term Storage Instructions Storage InstructionsGenerator Other Storage TipsTroubleshooting 2000W Generator 2000W Generator Emission Control System Warranty Year Consumer Use Years Years orTable DES Matières Symboles de danger et moyensDescription DE L Équipement Règles DE SécuritéLors DU Démarrage DE Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLorsque Léquipement Fonctionne Lorsque Vous Transportez OU Réparez LéquipementLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurLanceur Dispositif utilisé pour le démarrage du moteur Connaissez Votre GénérateurAvant LE Démarrage DU AssemblageMoteur Pour ajouter de lhuile Ajoutez de lessenceLors DE Lajout DU Carburant Utilisation DE LA Génératrice Emplacement de la génératriceMise à la terre du système Branchement au système électrique dun édificeDémarrage du moteur Utilisation DU GénérateurBranchement des charges électriques Recharge dune batterieArrêt du moteur Système dalerte de niveau dhuileRallonges Fiches DE ConnexionFonctionnement PAR Temps Froid Prise de 120 volts CA, 15 ampèresAbri Permanent Pour Temps Froids Capacité NE Surchargez PAS Votre GénérateurGestion de la consommation ExempleCaractéristiques Renseignements Techniques SUR LE MoteurPuissance nominale Caractéristiques de la génératriceDispositif Antipollution Recommandations Générales DentretienEntretien DU Générateur Pour nettoyer le générateurEntretien DU Moteur Avertissement Nettoyage/Remplacement de la bougie dallumageVérification du niveau dhuile Vidange de lhuile moteurNettoyage de lécran pare-étincelles Entretien du filtre à airSystème de refroidissement à air Pour nettoyer ou remplacer le filtre à airDirectives dentreposage à long terme Directives DentreposageGénératrice Autres conseils dentreposageDépannage Garantie DU Dispositif Antipollution Garantie Limitée Descripción DEL Equipo Tabla DE ContenidosReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito PeligroCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Bujía Conozca SU GeneradorEtiqueta de Datos Conexión de TierraAntes DE Darle Arranque AL Generador MontajeSeleccione una viscosidad de acuerdo a la tabla siguiente Añadir GasolinaPara Añadir Aceite al Motor Cuando Añada CombustibleTierra del Sistema USO DEL GeneradorConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorEncienda el Motor Operando EL Generador PrecauciónConexion De Cargas Electricas Procedimiento de Carga de la BateriaDetener el Motor Aceite Sistema AlertaCables DE Extensión Enchufes DE Conexión PrecauciónOperación Durante UN Clima Frío Receptáculo de 120 Voltios ACFigura 45 Refugio Frío Permanente del Tiempo Capacidad No Sobrecargue EL GeneradorControl de la Energía EjemploEspecificaciones DEL Producto Información Técnica Sobre EL MotorPotencia Nominal Especificaciones del GeneradorMantenimiento DEL Generador Recomendaciones GeneralesControl DE Emisiones Limpieza del GeneradorVerfique el Nivel de Aceite Mantenimiento DEL Motor AdvertenciaCambiar el Aceite del Motor Limpie/Reemplace la BujíaLimpieza del Filtro del Amortiguador de Chispas Mantenimiento del Filtro de AireSistema de Refrigeración de Aire Para limpiar o sustituir el filtro de aireInstrucciones de Almacenamiento a Largo Plazo Instrucciones DEL AlmacenamientoGenerador Otros Consejos de AlmacenamientoNotas Diagnóstico Y Reparación DE Averías Problema Causa SoluciónGarantia DEL Sistema DE Control DE Emisiones Garantía Limitada