Briggs & Stratton 30239 owner manual Add Fuel, To Add Engine Oil, When Adding Fuel

Page 7

2000W Generator

1.Choose a viscosity according to the table below:

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5W-30, 10W-30

 

 

 

 

 

 

 

 

 

 

 

Synthetic 5W-30, 10W-30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

°F

-20

0

20

32

40

60

80

100

°C

-30

 

-20

-10

 

 

0

10

20

30

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STARTING TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE

*The use of multi-viscosity oils (5W-30, 10W-30, etc.) in temperatures above 40°F (4°C) will result in higher than normal oil consumption. When using a multi-viscosity oil, check oil more frequently.

**If using SAE 30 oil in temperatures below 40°F (4°C), it will result in hard starting and possible engine bore damage due to inadequate lubrication.

NOTE: Synthetic oil meeting ILSAC GF-2, API certification mark and API service symbol with “SJ/CF ENERGY CONSERVING” or higher, is an acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.

To Add Engine Oil:

2.Place the generator on a level surface.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane with equipment. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion as shown in Figure 3.

3.Remove oil filler cap and wipe dipstick clean (Figure 2).

Figure 2 — Adding Engine Oil

Oil Filler Neck

4.If the oil level is not at the point of overflowing from the oil filler neck, slowly fill engine with recommended oil.

5.Reinstall oil filler cap and tighten securely.

6.Check the engine oil level before starting each time thereafter.

Add Fuel

NOTE: This gasoline engine is certified to operate on gasoline.

Figure 3 — Fuel Level

1.5” Airspace

NOTE: Occasionally clear the fuel strainer of any dirt, rust, or other particulate matter.

4.Install fuel cap and wipe up any spilled fuel.

Occasionally you may hear a light “spark knock” or “pinging” (metallic rapping noise) while operating under heavy loads. This is no cause for concern. If spark knock or pinging occurs at a steady engine speed under normal load, change brands of fuel or obtain a higher octane rated fuel. If pinging or spark knock persists, see your local Briggs & Stratton repair center.

7

Image 7
Contents 030239 2000W Safety Rules Table of ContentsEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorEngine ON/OFF Switch Engine ON/OFF Switch Used to stop a running engineKnow Your Generator Before Starting Engine AssemblyAdd Fuel When Adding FuelTo Add Engine Oil Generator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundGenerator OperatingStarting the Engine Oil Alert System Charging a BatteryConnecting Electrical Loads Stopping the EngineVolt AC, 15 Amp Receptacle Volt DC Accessory JackReceptacles Cold Weather OperationPermanent Cold Weather Shelter Remove shelter when temperatures are above 40F 4CExample Power ManagementDont Overload Generator CapacityEngine Specifications Product SpecificationsPower Ratings Generator SpecificationsGenerator Cleaning Generalgenerator Recommendations MaintenanceEmission Control Checking Oil Level Engine MaintenanceClean/Replace Spark Plug Clean area around oil drain plug FigureAir Cooling System Service Air CleanerClean Spark Arrester Screen To clean or replace air cleanerOther Storage Tips Storage InstructionsLong Term Storage Instructions GeneratorTroubleshooting 2000W Generator 2000W Generator Emission Control System Warranty Year Consumer Use Years Years orRègles DE Sécurité Symboles de danger et moyensTable DES Matières Description DE L ÉquipementLorsque Vous Transportez OU Réparez Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Léquipement FonctionneLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurLanceur Dispositif utilisé pour le démarrage du moteur Connaissez Votre GénérateurAvant LE Démarrage DU AssemblageMoteur Pour ajouter de lhuile Ajoutez de lessenceLors DE Lajout DU Carburant Branchement au système électrique dun édifice Emplacement de la génératriceUtilisation DE LA Génératrice Mise à la terre du systèmeDémarrage du moteur Utilisation DU GénérateurSystème dalerte de niveau dhuile Recharge dune batterieBranchement des charges électriques Arrêt du moteurPrise de 120 volts CA, 15 ampères Fiches DE ConnexionRallonges Fonctionnement PAR Temps FroidAbri Permanent Pour Temps Froids Exemple NE Surchargez PAS Votre GénérateurCapacité Gestion de la consommationCaractéristiques de la génératrice Renseignements Techniques SUR LE MoteurCaractéristiques Puissance nominalePour nettoyer le générateur Recommandations Générales DentretienDispositif Antipollution Entretien DU GénérateurVidange de lhuile moteur Nettoyage/Remplacement de la bougie dallumageEntretien DU Moteur Avertissement Vérification du niveau dhuilePour nettoyer ou remplacer le filtre à air Entretien du filtre à airNettoyage de lécran pare-étincelles Système de refroidissement à airAutres conseils dentreposage Directives DentreposageDirectives dentreposage à long terme GénératriceDépannage Garantie DU Dispositif Antipollution Garantie Limitée Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Opere EL Equipo PeligroCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Conexión de Tierra Conozca SU GeneradorBujía Etiqueta de DatosAntes DE Darle Arranque AL Generador MontajeCuando Añada Combustible Añadir GasolinaSeleccione una viscosidad de acuerdo a la tabla siguiente Para Añadir Aceite al MotorUbicación del Generador USO DEL GeneradorTierra del Sistema Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL Generador PrecauciónAceite Sistema Alerta Procedimiento de Carga de la BateriaConexion De Cargas Electricas Detener el MotorReceptáculo de 120 Voltios AC Enchufes DE Conexión PrecauciónCables DE Extensión Operación Durante UN Clima FríoFigura 45 Refugio Frío Permanente del Tiempo Ejemplo No Sobrecargue EL GeneradorCapacidad Control de la EnergíaEspecificaciones del Generador Información Técnica Sobre EL MotorEspecificaciones DEL Producto Potencia NominalLimpieza del Generador Recomendaciones GeneralesMantenimiento DEL Generador Control DE EmisionesLimpie/Reemplace la Bujía Mantenimiento DEL Motor AdvertenciaVerfique el Nivel de Aceite Cambiar el Aceite del MotorPara limpiar o sustituir el filtro de aire Mantenimiento del Filtro de AireLimpieza del Filtro del Amortiguador de Chispas Sistema de Refrigeración de AireOtros Consejos de Almacenamiento Instrucciones DEL AlmacenamientoInstrucciones de Almacenamiento a Largo Plazo GeneradorNotas Diagnóstico Y Reparación DE Averías Problema Causa SoluciónGarantia DEL Sistema DE Control DE Emisiones Garantía Limitada