Cisco Systems CF2001P user manual Connecting the Equipment Cables, Tor

Page 15

CF2001P

NEXT

Connecting the Equipment Cables

1.Insert a connector on the DTP32 cable (4)

into the I/O port on the side of the X-Rite, and then insert the other connector of the cable into port B on the selector.

4. Connect the IR port cable (8) to the printer.

C4004U562AA

C4004U559AA

2.Using the RS232 straight cable (5), connect the COM 1 port of the computer to port C on the selector.

NOTE

Make sure that the RS232 straight cable is connected to the COM 1 port of the com- puter.

C4004U560AA

3.Using RS232 straight cable (6), connect DB25 of the converter to port A of the selec-

tor.

C4004U561AA

5. Using a common screwdriver, tighten the four screws shown in the illustration, and then connect the harnesses of the IR port cable to the terminals on the converter.

TXA terminal: brown harness

TXB terminal: red harness

RXA terminal: orange harness

RXB terminal: blue harness

NOTE

Be sure to connect the harnesses of the IR port cable to the specified terminals.

Brown

Red

Blue

 

 

Orange

 

 

 

 

C4004U563AA

4004-7715-01

– 14 –

 

Image 15
Contents CF2001P Outline of the CF2001P System Setup Unpacking the Accessories UnpackingUnpacking the Printer Removing the Protective Tape and Packing Materials Installing the Imaging Units Installing the UnitsBlack imaging unit Clear plastic protective sheet is notPacking material therefore, do not remove Shaded area, is only attached toWhile carefully opening it otherwise, it may Installing the Oil-Coating UnitBe sure to install the imaging units in their correct slots Be sure to support the upper right-side doorRemove the oil-coating unit from its box Filling the Toner C4004U062AA Connecting the Cables Affix the label that corresponds with the installed optionsAffixing the Support Label Installing the Manual Holder Checking the Operation of the PrinterLoading Test Paper CF2001P Setting Up the Servicing EquipmentSetting Up the Converter Setting Up the Selector Tor Connecting the Equipment CablesRite Caliblation Click X-Rite Calibration in the Tech. Rep. Mode screen Dialog box appears if the auto-cal strip was read correctly Turn the cyan test pattern to its original ori If the cyan test pattern is read correctly Read the Pattern of Cyan disappears fromDialog box Checking the Date Setting Making System SettingSpecifying the Serial Number Specifying Who Performs Replacements Printing the List Click Image Processing Select the C Clear key to erase the entered number To set the Energy Save Mode parameterTo set the Sleep Mode parameter Tray Loading PaperSlide the lateral guides against the edges Paper Checking the Paper Reference Position for PF-118 Adjusting the OptionsClick PRT Area Adjusting the Paper Reference Position for PF-118 Click Machine Adjust Click Left Margin Pattern Do not measure from the back of the testChecking the Hole-Punching Positions for FN-107 Connecting the Telephone Cables Setting DT-105 USA and Canada onlyTransmission Settings Precautions for Connecting a Telephone to the Data TerminalDate/Time Settings Maintenance Center Billing Center Settings Clearing the Maintenance RAMEnter the service representative’s ID code If the number is not 6-digits long, add 0 at the beginning DT SettingsSetting the Telephone Number Initial Transmission Return