CF2001P
NEXT
C4004P565CA
C4004P597CA
4.Check that the External Panel Controller appears in the computer screen, and then display the Tech. Rep. Mode screen. (For details about displaying the Tech. Rep. Mode screen, refer to the Service Manual.)
NOTE
If the basic screen does not appear in the External Panel Controller, turn the printer off. Restart the External Panel Controller, and then turn the printer on again.
5.Click [X-Rite Calibration] in the Tech. Rep. Mode screen.
7.After the test patterns are printed, check that the message appears, and then click the Start key in the External Panel Controller.
C4004P569CA
8.Check that the dialog box appears, set the selector knob to “B”, and then click [OK] in the dialog box.
C4004P570CA
C4004U571AA
6.Check the message that appears, and then click the Start key in the External Panel Con- troller.
Test patterns are printed for the four colors. (Cyan, Magenta, Yellow, Black)
NOTE
C4004P567CA
• Since it may take some time to output the test patterns (about 2 minutes), wait until
Test patterns printing is finished.
• During printing, do not open the front door. If the front door is opened, restart the procedure from step 1.
9.Check that the dialog box appears, and then click [Yes] in the dialog box.
C4004P572CA
10.When the dialog box appears, the
C4004U568AA
C4004P573CA
– 16 – | |
|