Powerware FE/QFE UPS manual Specifications

Page 59

C H A P T E R

8

 

 

 

 

 

 

SPECIFICATIONS

 

 

 

 

 

 

Table 9. FE and QFE 500 VA–3.1 kVA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

l

 

 

GBB uWA

IBB uWA

LGB uWA

C9CG WA

C9F uWA

C9L uWA

D9C uWA

E9C uWA

 

 

 

EGBv

GBBv

HBBv

LBBv

Cv

C9DG

C9G v

D9D v

 

 

 

 

 

 

 

 

 

 

 

 

AC Input Voltage and Current, Standard Charger

 

 

 

 

 

 

 

 

 

 

 

 

 

FE:

120 Vac

4.6A

5.6A

6.6A

8.9A

11A

16A

19A

25A

 

208

Vac1

2.4A

2.8A

3.7A

5.0A

6.0A

9.2A

11A

14A

 

220

Vac

2.3A

2.7A

2.5A

4.6A

5.8A

7.8A

9.4A

12A

 

240

Vac1

2.1A

2.5A

3.2A

4.2A

5.3A

8.2A

9.2A

12A

QFE:

120 Vac

4.4A

5.8A

7.0A

8.4A

11A

15A

16A

24A

 

220

Vac

2.6A

3.9A

4.4A

4.9A

5.7A

7.9A

8.2A

13A

 

230

Vac

2.5A

3.8A

4.2A

4.6A

5.4A

7.5A

7.8A

12A

 

240

Vac

2.4A

3.5A

4.0A

4.4A

5.2A

7.2A

7.4A

12A

 

 

 

 

 

 

 

 

 

Recommended

 

 

 

 

 

 

 

 

AC Input Service:

10A

10A

10A

15A

15A

20A

20A

30A

60 Hz with

 

 

 

 

 

 

 

 

120 Vac1

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Voltage and Maximum Output Current2

 

 

 

FE:

120 Vac

4.1A

5.9A

7.0A

9.3A

12A

15A

17A

26A

 

208

Vac

2.3A

3.3A

4.0A

5.3A

6.5A

8.4A

9.9A

15A

 

220

Vac

5.0A

6.1A

8.0A

9.0A

14A

 

240

Vac

2.1A

2.8A

3.4A

4.7A

5.6A

7.3A

8.6A

13A

QFE:

120 Vac

4.1A

5.7A

7.1A

9.4A

12A

14A

17A

25A

 

220

Vac

2.2A

3.2A

3.8A

5.0A

6.4A

7.9A

9.3A

14A

 

230

Vac

2.2A

3.1A

3.6A

4.8A

6.2A

7.6A

8.9A

13A

 

240

Vac

2.1A

2.9A

3.5A

4.6A

5.9A

7.2A

8.5A

13A

 

 

 

 

 

 

 

 

 

Efficiency on AC

85%

86%

85%

88%

88%

90%

90%

91%

Line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On Line

 

 

 

 

 

 

 

 

 

BTU/hour:

 

210

277

361

372

465

474

568

742

kW/hour:

 

.062

.081

.106

.109

.136

.139

.166

.217

 

 

 

 

 

 

 

 

 

Audible Noise

41

41

47

49

49

51

51

51

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

Powerware® FERRUPS FE/QFE UPS (500 VA–18 kVA) User’s Guide : Rev A www.powerware.com

 

53

Image 59
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS For Users in Germany Class a EMC StatementsFCC Part ICES-003 Table of Contents Options Alarm Code Summary Service and SupportKVA Models 500 VA-3.1 kVA Models IntroductionIdentifying Your UPS Page R N I N G Safety WarningsP O R T a N T S a F E T Y I N S T R U C T I O N S N G E RR E SikkerhedsanvisningerU T I O N A R S C H U W I N G Belangrijke VeiligheidsinstructiesV a R S E L V a a RR O I T U S Tarkeita TurvaohjeitaG E L E T A R aR O Consignes de sécuritéH T U N G SicherheitswarnungenR N U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi V E R T E N Z a Avvisi di sicurezzaR I C O L O R L I G Viktig SikkerhetsinformasionT E N Z I O N E V E R T Ê N C I a Regulamentos de SegurançaR S I K T I G I D a D OÐåäóïðåæäåíèå Ïðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòèR I G O ÎïàñíîV E R T E N C I a Advertencias de SeguridadÑòîðîæíî L I G R OR a SäkerhetsföreskrifterE C a U C I Ó N K T I G T Startup for the FE and QFE 500 VA-3.1 kVA UPS UPS StartupLd The AC Line indicator illuminates see Figure Startup for the FE and QFE 4.3-18 kVA UPS 7LPH ProgramDWH Where is the Battery Ah value from Table9ME External Battery Pack Ah ValuesRear Panels On/Off Switch Power Cord RS-232 Communication PortRS-232 Communication Port On/Off Switch SwitchKVA Models PanelOperation Front Panel IndicatorsIndicator Status Changing Operating Modes Using the Control PanelOperating Modes Entering PasswordsLocking and Unlocking the Control Panel Displaying and Changing ParametersRemote Control Panel Using the Configuration MenuInverter Test Battery TestAutomatic System Test Logic TestParameters ParametersLow DC power is turned offUPS VA Limit, parameterUsed by your equipment Configured for use with your networkSwitch is in the OFF position Shows -63cEach part of the system test see UPS ShutdownInverter Logs on ExplanationU T I O N Extended Power Outages Page Communication Powerware Software SuiteCommunication Port Connecting a Terminal or Computer to the RS-232 Port DB-9 to UPS Pinout Action Key Sequence DB-25 Port SettingsKeystroke Commands Commands Entering Commands from a Terminal or ComputerCommand then clears the minimum and maximum values CommandDelay Shows a list of terminal/computer commandsCancels a shutdown started with the shutdown command PasswordUPS restar hortly after power returns Shutdown cancelRemote Shutdown Remote MonitoringPage Options Page Maintenance Page Specifications FE and QFE 4.3-18 kVA 103A 149A Audible Noise dB Runtime minutes Full Load Half Load WeightF9E uWA G9E uWA IuWA E9I I9GElectrical Input and Output Battery Environmental and SafetyPage Alarms TroubleshootingAlarms Temperature probe is missing or To start the user test alarm fromAlarm off Possible microprocessor problemUPS off and contact your service Alarm and Inverter LogsReading the Alarm Log from a Control Panel Requires service RepresentativeReading the Inverter Log from a Control Panel Inverter Codes Reading the Alarm Log from a Terminal or ComputerLow AC Output Alarm Code SummaryLow Battery Reading the Inverter Log from a Terminal or Computer852--3030 Service and Support