Powerware FE/QFE UPS manual Class a EMC Statements, FCC Part ICES-003, For Users in Germany

Page 4

Class A EMC Statements

FCC Part 15

NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ICES-003

This Class A Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES-003.

Cet appareil numérique de la classe A respecte toutes les exigences du Reglement sur le matériel brouilleur du Canada.

For Users in Germany

We hereby certify that the uninterruptible power system (QFE 500 VA, 700 VA, 850 VA, 1.15 kVA, 1.4 kVA, 1.8 kVA,

2.1kVA, 3.1 kVA, 4.3 kVA, 5.3 kVA, 7 kVA, 10 kVA, 12.5 kVA, and 18 kVA) complies with the RFI suppression requirements of Vfg. 243/1991 and Vfg. 46/1992. The German Postal Service was notified that the equipment is being marketed. The German Postal Service has the right to retest the equipment and verify compliance.

Hiermit wird bescheinigt, daß die unterbrechungsfreie Stromversorgung (QFE 500 VA, 700 VA, 850 VA, 1.15 kVA,

1.4kVA, 1.8 kVA, 2.1 kVA, 3.1 kVA, 4.3 kVA, 5.3 kVA, 7 kVA, 10 kVA, 12.5 kVA, and 18 kVA) in Übereinstimmung mit den Bestimmungen der Vfg. 243/1991 und Vfg. 46/1992 funkentstört ist. Der Deutschen Bundespost wurde das Inverkehrbringen dieses Gerätes angezeigt und die Berechtigung zur Überprüfung der Serie auf Einhaltung der Bestimmung eingeräumt.

Powerware reserves the right to change specifications without prior notice.

Powerware and CheckUPS are registered trademarks and EnviroCom is a trademark of Powerware Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

HyperTerminal is a registered trademark of Hilgraeve. TeleVideo is a registered trademark of TeleVideo, Inc. WYSE.is a registered trademark of WYSE Technology Inc.

Copyright 2002 Powerware, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Powerware.

Image 4
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS FCC Part ICES-003 Class a EMC StatementsFor Users in Germany Table of Contents Alarm Code Summary Service and Support OptionsIdentifying Your UPS IntroductionKVA Models 500 VA-3.1 kVA Models Page Safety Warnings P O R T a N T S a F E T Y I N S T R U C T I O N SN G E R R N I N GU T I O N SikkerhedsanvisningerR E Belangrijke Veiligheidsinstructies V a R S E LV a a R A R S C H U W I N GTarkeita Turvaohjeita G E L E TA R a R O I T U SConsignes de sécurité R OR N U N G SicherheitswarnungenH T U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi R I C O L O Avvisi di sicurezzaV E R T E N Z a T E N Z I O N E Viktig SikkerhetsinformasionR L I G Regulamentos de Segurança R S I K T I GI D a D O V E R T Ê N C I aÏðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòè R I G OÎïàñíî ÐåäóïðåæäåíèåAdvertencias de Seguridad ÑòîðîæíîL I G R O V E R T E N C I aE C a U C I Ó N SäkerhetsföreskrifterR a K T I G T UPS Startup Startup for the FE and QFE 500 VA-3.1 kVA UPSLd The AC Line indicator illuminates see Figure Startup for the FE and QFE 4.3-18 kVA UPS Program 7LPHWhere is the Battery Ah value from Table DWHExternal Battery Pack Ah Values 9MEOn/Off Switch Power Cord RS-232 Communication Port RS-232 Communication Port On/Off SwitchSwitch Rear PanelsPanel KVA ModelsFront Panel Indicators OperationIndicator Status Using the Control Panel Changing Operating ModesEntering Passwords Operating ModesDisplaying and Changing Parameters Locking and Unlocking the Control PanelUsing the Configuration Menu Remote Control PanelBattery Test Automatic System TestLogic Test Inverter TestParameters ParametersDC power is turned off UPSVA Limit, parameter LowConfigured for use with your network Switch is in the OFF positionShows -63c Used by your equipmentUPS Shutdown Inverter Logs onExplanation Each part of the system test seeU T I O N Extended Power Outages Page Powerware Software Suite CommunicationCommunication Port Connecting a Terminal or Computer to the RS-232 Port DB-9 to UPS Pinout Keystroke Commands DB-25 Port SettingsAction Key Sequence Entering Commands from a Terminal or Computer CommandsCommand DelayShows a list of terminal/computer commands Command then clears the minimum and maximum valuesPassword UPS restar hortly after power returnsShutdown cancel Cancels a shutdown started with the shutdown commandRemote Monitoring Remote ShutdownPage Options Page Maintenance Page Specifications FE and QFE 4.3-18 kVA Audible Noise dB Runtime minutes Full Load Half Load Weight F9E uWA G9E uWA IuWAE9I I9G 103A 149AElectrical Input and Output Environmental and Safety BatteryPage Troubleshooting AlarmsAlarms To start the user test alarm from Alarm offPossible microprocessor problem Temperature probe is missing orAlarm and Inverter Logs Reading the Alarm Log from a Control PanelRequires service Representative UPS off and contact your serviceReading the Inverter Log from a Control Panel Reading the Alarm Log from a Terminal or Computer Inverter CodesAlarm Code Summary Low BatteryReading the Inverter Log from a Terminal or Computer Low AC OutputService and Support 852--3030