Powerware FE/QFE UPS Safety Warnings, P O R T a N T S a F E T Y I N S T R U C T I O N S, N G E R

Page 9

C H A P T E R 2

SAFETY WARNINGS

Read the following precautions before you install the UPS.

I M P O R T A N T S A F E T Y I N S T R U C T I O N S

SAVE THESE INSTRUCTIONS. This manual contains important instructions that you should follow during installation and maintenance of the UPS and batteries. Please read all instructions before operating the equipment and save this manual for future reference.

D A N G E R

This UPS contains LETHAL VOLTAGES. All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the UPS.

W A R N I N G

:This UPS contains its own energy source (batteries). The output receptacles may carry live voltage even when the UPS is not connected to an AC supply.

:Do not remove or unplug the input cord when the UPS is turned on. This removes the safety ground from the UPS and the equipment connected to the UPS.

:To reduce the risk of fire or electric shock, install this UPS in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40°C (104°F). Do not operate near water or excessive humidity (95% max).

:To comply with international standards and wiring regulations, the total equipment connected to the output of this UPS must not have an earth leakage current greater than 1.5 milliamperes.

Powerware® FERRUPS FE/QFE UPS (500 VA–18 kVA) User’s Guide : Rev A www.powerware.com

3

Image 9
Contents Powerware Ferrups FE/QFE UPS Page Powerware Ferrups FE/QFE UPS Class a EMC Statements FCC Part ICES-003For Users in Germany Table of Contents Options Alarm Code Summary Service and SupportIntroduction Identifying Your UPSKVA Models 500 VA-3.1 kVA Models Page P O R T a N T S a F E T Y I N S T R U C T I O N S Safety WarningsN G E R R N I N GSikkerhedsanvisninger U T I O NR E V a R S E L Belangrijke VeiligheidsinstructiesV a a R A R S C H U W I N GG E L E T Tarkeita TurvaohjeitaA R a R O I T U SR O Consignes de sécuritéSicherheitswarnungen R N U N GH T U N G „Ò·Ûfl· C›„ÈÛÙ.ÃÁ˜ÒÁÙÈÏÔfi95%ÔÈÂflÙÂUPSÍÔÌÙ‹ÛÂÌÂÒ¸fi Avvisi di sicurezza R I C O L OV E R T E N Z a Viktig Sikkerhetsinformasion T E N Z I O N ER L I G R S I K T I G Regulamentos de SegurançaI D a D O V E R T Ê N C I aR I G O Ïðåäóïðåæäåíèÿ ïî ìåðàì áåçîïàñíîñòèÎïàñíî ÐåäóïðåæäåíèåÑòîðîæíî Advertencias de SeguridadL I G R O V E R T E N C I aSäkerhetsföreskrifter E C a U C I Ó NR a K T I G T Startup for the FE and QFE 500 VA-3.1 kVA UPS UPS StartupLd The AC Line indicator illuminates see Figure Startup for the FE and QFE 4.3-18 kVA UPS 7LPH ProgramDWH Where is the Battery Ah value from Table9ME External Battery Pack Ah ValuesRS-232 Communication Port On/Off Switch On/Off Switch Power Cord RS-232 Communication PortSwitch Rear PanelsKVA Models PanelOperation Front Panel IndicatorsIndicator Status Changing Operating Modes Using the Control PanelOperating Modes Entering PasswordsLocking and Unlocking the Control Panel Displaying and Changing ParametersRemote Control Panel Using the Configuration MenuAutomatic System Test Battery TestLogic Test Inverter TestParameters ParametersUPS DC power is turned offVA Limit, parameter LowSwitch is in the OFF position Configured for use with your networkShows -63c Used by your equipmentInverter Logs on UPS ShutdownExplanation Each part of the system test seeU T I O N Extended Power Outages Page Communication Powerware Software SuiteCommunication Port Connecting a Terminal or Computer to the RS-232 Port DB-9 to UPS Pinout DB-25 Port Settings Keystroke CommandsAction Key Sequence Commands Entering Commands from a Terminal or ComputerDelay CommandShows a list of terminal/computer commands Command then clears the minimum and maximum valuesUPS restar hortly after power returns PasswordShutdown cancel Cancels a shutdown started with the shutdown commandRemote Shutdown Remote MonitoringPage Options Page Maintenance Page Specifications FE and QFE 4.3-18 kVA F9E uWA G9E uWA IuWA Audible Noise dB Runtime minutes Full Load Half Load WeightE9I I9G 103A 149AElectrical Input and Output Battery Environmental and SafetyPage Alarms TroubleshootingAlarms Alarm off To start the user test alarm fromPossible microprocessor problem Temperature probe is missing orReading the Alarm Log from a Control Panel Alarm and Inverter LogsRequires service Representative UPS off and contact your serviceReading the Inverter Log from a Control Panel Inverter Codes Reading the Alarm Log from a Terminal or ComputerLow Battery Alarm Code SummaryReading the Inverter Log from a Terminal or Computer Low AC Output852--3030 Service and Support