Baldor MN850, Baldor manual K3 BIT Mask

Page 38

Title

P#

Parameter

 

 

 

 

Description

 

 

 

 

Parameters

P60

K2 Bit Mask (P59 bit selected for K2)

Sets the bit in the parameter selected by P59 that operates the relay

Continued

 

 

K2 on the control card. The preset is P8:Status 1, Bit3 (Top of Ramp

 

 

 

or Full Volts). (P60 operates with P59).

 

 

 

7 6

5

4 3 2 1

0

Bits

 

 

 

1 0

0

0 0 0 0

0

 

 

 

 

0 1

0

0 0 0 0

0

 

 

 

 

0 0

1

0 0 0 0

0

 

 

 

 

0 0

0

1 0 0 0

0

 

 

 

 

0 0

0

0 1 0 0

0

(Preset)

 

 

 

0 0

0

0 0 1 0

0

 

 

 

 

0 0

0

0 0 0 1

0

 

 

 

 

0 0

0

0 0 0 0

1

 

 

 

 

 

 

P61

MAP K3 TO (Parameter)

Value is the destination parameter number for the K3 bit.

 

 

 

Parameter 62 is the mask for P61 (Map K3 To).

 

 

 

 

 

P62

K3 BIT MASK

Parameter 62 is the mask for P61 (Map K3 To).

 

 

 

 

 

P63

MAP K4 TO (Parameter)

Value is the destination parameter number for the K4 bit.

 

 

 

Parameter 64 is the mask for P63 (Map K4 To).

 

 

 

 

 

P64

K4 BIT MASK

Parameter 64 is the mask for P63 (Map K4 To).

 

 

 

 

 

P65

Map I/P1 To (Parameter)

The parameter number that will control Input 1 on the control card.

 

 

 

The preset is P52: User Flags 1–2. (Parameter 66 is the mask for

 

 

 

P65, Map I/P1 To). (Mapped to means electronic transfer of the

 

 

 

analog value.)

 

 

 

 

 

 

 

P66

I/P1 Bit Mask (P65 bit selected for I/P1)

Sets the bit in the parameter selected by P65 that operates Input 1 of

 

 

 

the control card. The preset is P52:User Flags 1–2, Bit4 (Board

 

 

 

Start/Stop). (Parameter 66 is the mask for P65, Map I/P1 To).

 

 

 

7 6

5

4 3 2 1

0

Bits

 

 

 

1 0

0

0 0 0 0

0

 

 

 

 

0 1

0

0 0 0 0

0

 

 

 

 

0 0

1

0 0 0 0

0

 

 

 

 

0 0

0

1 0 0 0

0

(Preset)

 

 

 

0 0

0

0 1 0 0

0

 

 

 

 

0 0

0

0 0 1 0

0

 

 

 

 

0 0

0

0 0 0 1

0

 

 

 

 

0 0

0

0 0 0 0

1

 

 

 

 

 

 

P67

Map I/P2 To (Parameter)

The parameter number that will control Input 2 on the control card.

 

 

 

The preset is P0. (Parameter 68 is the mask for P67, Map I/P2 To).

 

 

 

(Mapped to means electronic transfer of the analog value.)

 

 

 

 

 

P68

I/P2 Bit Mask (P67 bit selected for I/P2)

Parameter 68 is the mask for P67, Map I/P2 To.

 

 

 

 

 

P69

Map I/P3 To (Parameter)

The parameter number that will control Input 3 on the control card.

 

 

 

The preset is P0. (Parameter 70 is the mask for P69, Map I/P3 To).

 

 

 

(Mapped to means electronic transfer of the analog value.)

 

 

 

 

 

P70

I/P3 Bit Mask (P69 bit selected for I/P3)

Parameter 70 is the mask for P69, Map I/P3 To.

 

 

 

 

 

 

 

 

MN850

Parameter Index 4-11

Image 38
Contents Digital Soft-Start Table of Contents Appendix C Appendix aAppendix B Appendix DIntroduction Limited WarrantySection General Information Safety Notice PrecautionsPhysical Location Section InstallationReceiving, Inspection and Storage Air Flow Clearance RequirementsCover Removal Mounting Instructions For clearance mounting holes Tools RequiredMounting Instruction For tapped mounting holes AC Main Circuit Catalog Number Connection DescriptionsUL Required Fuses for Short Circuit Rating Baldor Control SupplyMotor Overload and Thermal Protection Digital Soft-StartIn-Delta Soft-Start Connections Baldor DigitalNEC Wire Size and Protection Devices 45x20115 / 230VAC Three Wire ControlTwo Wire Control Top of Ramp Bypass Connection 115/230VACMotor Reversing Connection To AC InputInstallation Shock MountingOverview Pre-Start ChecklistSection Operation Sure to check the following itemsKeypad Operation Start-Up ProcedureKeypad Mode Switch System Program Menu Data Status Entry Action Description Display CommentsData Entry Mode System Status Mode Description Display CommentsMenu Mode Operating ModesMenu Structure Diagram Menu StructureMenu Navigation Examples Menu NavigationSave Param Motor Starting Key Terms Motor Starting Definitions TermApplications Auto Features Optimising Current Remote Start and Running the MotorMotor Stopping Definitions Term Stopping the MotorBasic Menu Section Parameter IndexMenu Descriptions Applications MenuParameter Index MN850 Advanced Menu Auto Features Menu Inputs Menu Password MenuPermanent Store Menu Trips Menu Outputs MenuParameters Menu Parameter Description Parameter Descriptions Title Parameter DescriptionRatedCurrent x P52 User Flags Definition Preset Value ExampleK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Power Off Checks Section TroubleshootingFault Trip Messages Preliminary ChecksTroubleshooting Guide Indication Corrective Action230/460VAC 3 Phase Relay and Contactor Coils Analog SignalsElectrical Noise Considerations Special Motor ConsiderationsSection Specifications and Product Data IdentificationOperating Conditions Input RatingsStorage Conditions 230V 460V 575V Mounting Dimensions Size10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix a CE Guidelines EMC Conformity and CE MarkingControl EMC Installation Instructions Cable Screens GroundingAppendix MN850 Title Parameter Adjustable Range Factory User Setting Appendix B Parameter ValuesApplications MN850 MN850 Applications B-3 Section General Information Appendix C Replacement Parts Voltage Independent Parts Description575VAC Parts Description Appendix D Voltage Surge Protection GroundingGrounded or Symbol High Resistance Ground Control Enclosure Voltage Surge Protection MN850Corner or Center-Tap Symbol Grounded Control Enclosure Table D-1 Baldor MOV SpecificationsVoltage Surge Protection MN850 Appendix E 340 810 500 250 Remote Keypad Mounting Template500 Baldor Electric Company  Baldor Electric Company MN850 03 C&J1500