Baldor Baldor, MN850 manual 575VAC Parts Description

Page 63

575VAC Parts

 

 

PART No.

Description

SSD1PSCR059

1

Phase SCR pair for 44, 59 A

SSD1PSCR8030

1

Phase SCR pair for 9, 16, 23, 30 A

SSD1PSCR8059

1

Phase SCR pair for 44, 59 A

SSD1PSCR8146

1

Phase SCR pair for 72, 85, 105, 146 A

SSD1SCR8202

1

Phase SCR pair for 174, 202 A

SSD3PC8242

1

Phase power cell for 242, 300A

SSD1SCR8300

Single SCR 242, 300A

SSD3SCR8370

1

Phase power cell for 370 A

SSD1SCR8370

Single SCR 370A

SSDPC8600

1

Phase power cell for 500, 600 A

SSD1SCR8600

Single SCR 500, 600A

SSDPC8900

1

Phase power cell for 750, 900 A

SSD1SCR8900

Single SCR 900A

SSDEB8009

Standard control board for 9 A

SSDEB8016

Standard control board for 16 A

SSDEB8023

Standard control board for 23 A

SSDEB8030

Standard control board for 30 A

SSDEB8044

Standard control board for 44 A

SSDEB8059

Standard control board for 59 A

SSDEB8072

Standard control board for 72 A

SSDEB8085

Standard control board for 85 A

SSDEB8105

Standard control board for 105 A

SSDEB8146

Standard control board for 146 A

SSDEB8174

Standard control board for 174 A

SSDEB8202

Standard control board for 202 A

SSDEB8242

Standard control board for 242 A

SSDEB8300

Standard control board for 300 A

SSDEB8370

Standard control board for 370 A

SSDEB8500

Standard control board for 500 A

SSDEB8600

Standard control board for 600 A

SSDEB8750

Standard control board for 750 A

SSDEB8900

Standard control board for 900 A

SSDCBLGT8059

Gate/Cathode wires, 16–59 A

SSDCBLGT8146

Gate/Cathode wires, 72–146 A

SSDCBLGT8370

Gate/Cathode wires, 174–370 A

SSDCBLGT8900

Gate/Cathode wire assembly, 500–900 A

C-2 Appendix

MN850

Image 63
Contents Digital Soft-Start Table of Contents Appendix D Appendix aAppendix B Appendix CLimited Warranty Section General InformationIntroduction Precautions Safety NoticeAir Flow Clearance Requirements Section InstallationReceiving, Inspection and Storage Physical LocationCover Removal Tools Required Mounting Instruction For tapped mounting holesMounting Instructions For clearance mounting holes AC Main Circuit Connection Descriptions UL Required Fuses for Short Circuit RatingCatalog Number Digital Soft-Start Control SupplyMotor Overload and Thermal Protection BaldorBaldor Digital In-Delta Soft-Start Connections45x20 NEC Wire Size and Protection DevicesThree Wire Control Two Wire Control115 / 230VAC 115/230VAC Top of Ramp Bypass ConnectionTo AC Input Motor Reversing ConnectionShock Mounting InstallationSure to check the following items Pre-Start ChecklistSection Operation OverviewAction Description Display Comments Start-Up ProcedureKeypad Mode Switch System Program Menu Data Status Entry Keypad OperationOperating Modes System Status Mode Description Display CommentsMenu Mode Data Entry ModeMenu Structure Menu Structure DiagramMenu Navigation Menu Navigation ExamplesSave Param Motor Starting Definitions Term Motor Starting Key TermsApplications Auto Features Remote Start and Running the Motor Optimising CurrentStopping the Motor Motor Stopping Definitions TermApplications Menu Section Parameter IndexMenu Descriptions Basic MenuParameter Index MN850 Advanced Menu Auto Features Menu Password Menu Permanent Store MenuInputs Menu Outputs Menu Parameters MenuTrips Menu Parameter Description Title Parameter Description Parameter DescriptionsRatedCurrent x Example P52 User Flags Definition Preset ValueK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Preliminary Checks Section TroubleshootingFault Trip Messages Power Off ChecksIndication Corrective Action Troubleshooting Guide230/460VAC 3 Phase Special Motor Considerations Analog SignalsElectrical Noise Considerations Relay and Contactor CoilsIdentification Section Specifications and Product DataInput Ratings Storage ConditionsOperating Conditions 230V 460V 575V Size Mounting Dimensions10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 EMC Conformity and CE Marking Wiring of Shielded Screened CablesAppendix a CE Guidelines CE Declaration of ConformityControl Cable Screens Grounding EMC Installation InstructionsAppendix MN850 Appendix B Parameter Values Title Parameter Adjustable Range Factory User SettingApplications MN850 MN850 Applications B-3 Section General Information Voltage Independent Parts Description Appendix C Replacement Parts575VAC Parts Description Grounding Appendix D Voltage Surge ProtectionVoltage Surge Protection MN850 Grounded or Symbol High Resistance Ground Control EnclosureTable D-1 Baldor MOV Specifications Corner or Center-Tap Symbol Grounded Control EnclosureVoltage Surge Protection MN850 Appendix E Remote Keypad Mounting Template 500340 810 500 250  Baldor Electric Company MN850 03 C&J1500 Baldor Electric Company