Baldor MN850, Baldor manual 230V 460V 575V

Page 48

Standard Duty: Agitator, Compressor, Centrifuge, Fan, Blower, Chiller, Escalator, Pump,

Bandsaw, Low Inertia Fan, Small Pump.

Medium Duty: Mill, Conveyor, Drilling Press, Reciprocating Compressor, Elevator, Screw

Feeder, Grinder, Hammer Press, Mixer, Large Pump, High Inertia Fan, Pelletizer, Pulper, Flywheel

Press, Positive Displacement Pump, Circular Saw, Vibrating Screens.

Heavy Duty: Rock Crusher, Pulverizer, Separator, Chipper, Screw Compressor.

Catalog

Output

 

 

 

 

 

 

HP Ratings

 

 

 

 

 

 

Cont.

 

Standard Duty

 

 

Medium Duty

 

 

Heavy Duty

 

Number

 

 

 

 

 

 

Current

230V

 

460V

 

575V

230V

 

460V

 

575V

230V

 

460V

 

575V

 

 

 

 

 

 

 

MD7–009–CB

9A

 

 

5

 

 

 

 

5

 

 

 

 

 

 

 

MD7–016–CB

16A

5

 

10

 

 

 

 

7.5

 

 

 

 

5

 

 

MD7–023–CB

23A

7.5

 

15

 

 

5

 

10

 

 

 

 

7.5

 

 

MD7–030–CB

30A

10

 

20

 

 

7.5

 

15

 

 

 

 

10

 

 

MD7–044–CB

44A

15

 

30

 

 

10

 

20

 

 

5

 

15

 

 

MD7–059–CB

59A

20

 

40

 

 

15

 

30

 

 

7.5

 

20

 

 

MD7–072–CB

72A

25

 

50

 

 

15

 

40

 

 

10

 

30

 

 

MD7–085–CB

85A

30

 

60

 

 

20

 

50

 

 

15

 

40

 

 

MD7–105–CB

105A

40

 

75

 

 

30

 

60

 

 

20

 

50

 

 

MD7–146–CB

146A

50

 

100

 

 

40

 

75

 

 

30

 

60

 

 

MD7–174–CB

174A

60

 

125

 

 

50

 

100

 

 

40

 

75

 

 

MD7–202–CB

202A

75

 

150

 

 

60

 

125

 

 

50

 

100

 

 

MD7–242–CB

242A

100

 

200

 

 

75

 

150

 

 

60

 

125

 

 

MD7–300–CB

300A

125

 

250

 

 

100

 

200

 

 

75

 

150

 

 

MD7–370–CB

370A

150

 

300

 

 

125

 

250

 

 

100

 

200

 

 

MD7–500–CB

500A

200

 

400

 

 

150

 

300

 

 

125

 

250

 

 

MD7–600–CB

600A

 

 

500

 

 

200

 

400

 

 

150

 

300

 

 

MD7–750–CB

750A

 

 

600

 

 

 

 

500

 

 

200

 

400

 

 

MD7–900–CB

900A

 

 

700

 

 

 

 

600

 

 

 

 

500

 

 

MD8–009–CB

9A

 

 

5

 

7.5

 

 

5

 

5

 

 

 

 

 

MD8–016–CB

16A

5

 

10

 

10

 

 

7.5

 

7.5

 

 

5

 

5

MD8–023–CB

23A

7.5

 

15

 

20

5

 

10

 

10

 

 

7.5

 

7.5

MD8–030–CB

30A

10

 

20

 

25

7.5

 

15

 

20

 

 

10

 

10

MD8–044–CB

44A

15

 

30

 

40

10

 

20

 

30

5

 

15

 

20

MD8–059–CB

59A

20

 

40

 

50

15

 

30

 

40

7.5

 

20

 

30

MD8–072–CB

72A

25

 

50

 

60

15

 

40

 

50

10

 

30

 

40

MD8–085–CB

85A

30

 

60

 

75

20

 

50

 

60

15

 

40

 

50

MD8–105–CB

105A

40

 

75

 

100

30

 

60

 

75

20

 

50

 

60

MD8–146–CB

146A

50

 

100

 

 

40

 

75

 

125

30

 

60

 

100

MD8–174–CB

174A

60

 

125

 

150

50

 

100

 

 

40

 

75

 

 

MD8–202–CB

202A

75

 

150

 

200

60

 

125

 

150

50

 

100

 

125

MD8–242–CB

242A

100

 

200

 

250

75

 

150

 

200

60

 

125

 

150

MD8–300–CB

300A

125

 

250

 

 

100

 

200

 

 

75

 

150

 

 

MD8–370–CB

370A

150

 

300

 

300

125

 

250

 

 

100

 

200

 

 

MD8–500–CB

500A

200

 

400

 

400

150

 

300

 

250

125

 

250

 

300

MD8–600–CB

600A

 

 

500

 

500

200

 

400

 

400

150

 

300

 

400

MD8–750–CB

750A

 

 

600

 

600

 

 

500

 

500

200

 

400

 

500

MD8–900–CB

900A

 

 

700

 

700

 

 

600

 

600

 

 

500

 

600

MD8–1100–CB

1100A

 

 

800

 

800

 

 

700

 

700

 

 

600

 

600

MD8–1200–CB

1200A

 

 

900

 

900

 

 

800

 

800

 

 

700

 

700

MN850

Specifications and Product Data 6-3

Image 48
Contents Digital Soft-Start Table of Contents Appendix a Appendix BAppendix C Appendix DLimited Warranty Section General InformationIntroduction Safety Notice PrecautionsSection Installation Receiving, Inspection and StoragePhysical Location Air Flow Clearance RequirementsCover Removal Tools Required Mounting Instruction For tapped mounting holesMounting Instructions For clearance mounting holes AC Main Circuit Connection Descriptions UL Required Fuses for Short Circuit RatingCatalog Number Control Supply Motor Overload and Thermal ProtectionBaldor Digital Soft-StartIn-Delta Soft-Start Connections Baldor DigitalNEC Wire Size and Protection Devices 45x20Three Wire Control Two Wire Control115 / 230VAC Top of Ramp Bypass Connection 115/230VACMotor Reversing Connection To AC InputInstallation Shock MountingPre-Start Checklist Section OperationOverview Sure to check the following itemsStart-Up Procedure Keypad Mode Switch System Program Menu Data Status EntryKeypad Operation Action Description Display CommentsSystem Status Mode Description Display Comments Menu ModeData Entry Mode Operating ModesMenu Structure Diagram Menu StructureMenu Navigation Examples Menu NavigationSave Param Motor Starting Key Terms Motor Starting Definitions TermApplications Auto Features Optimising Current Remote Start and Running the MotorMotor Stopping Definitions Term Stopping the MotorSection Parameter Index Menu DescriptionsBasic Menu Applications MenuParameter Index MN850 Advanced Menu Auto Features Menu Password Menu Permanent Store MenuInputs Menu Outputs Menu Parameters MenuTrips Menu Parameter Description Parameter Descriptions Title Parameter DescriptionRatedCurrent x P52 User Flags Definition Preset Value ExampleK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Section Troubleshooting Fault Trip MessagesPower Off Checks Preliminary ChecksTroubleshooting Guide Indication Corrective Action230/460VAC 3 Phase Analog Signals Electrical Noise ConsiderationsRelay and Contactor Coils Special Motor ConsiderationsSection Specifications and Product Data IdentificationInput Ratings Storage ConditionsOperating Conditions 230V 460V 575V Mounting Dimensions Size10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 Wiring of Shielded Screened Cables Appendix a CE GuidelinesCE Declaration of Conformity EMC Conformity and CE MarkingControl EMC Installation Instructions Cable Screens GroundingAppendix MN850 Title Parameter Adjustable Range Factory User Setting Appendix B Parameter ValuesApplications MN850 MN850 Applications B-3 Section General Information Appendix C Replacement Parts Voltage Independent Parts Description575VAC Parts Description Appendix D Voltage Surge Protection GroundingGrounded or Symbol High Resistance Ground Control Enclosure Voltage Surge Protection MN850Corner or Center-Tap Symbol Grounded Control Enclosure Table D-1 Baldor MOV SpecificationsVoltage Surge Protection MN850 Appendix E Remote Keypad Mounting Template 500340 810 500 250 Baldor Electric Company  Baldor Electric Company MN850 03 C&J1500