Menu Navigation

This example shows how to go to the Inputs menu and map an input parameter.

 

 

 

 

 

 

 

 

Action

Description

 

Display

Comments

 

 

 

 

 

 

Apply Control Voltage

Keypad Display shows this

 

Baldor Soft Start

 

Logo display for 2 seconds.

(115VAC)

opening message.

 

 

 

 

 

 

 

 

 

If no faults the display will show

 

 

 

System Status mode.

 

 

 

 

 

 

 

Stopped & Ready

 

 

 

this message.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press ENTER key

 

 

APPLICATIONS

 

Press ENTER to access menu

 

 

 

 

 

mode.

 

 

 

 

AUTO FEATURES

 

 

 

 

 

 

 

Press

key

Scroll to the AUTO FEATURES

 

 

 

Press ENTER to access Basic

AUTO FEATURES

 

 

 

menu.

 

 

level 2 parameters if desired.

 

 

 

BASIC

 

 

 

 

 

 

 

Press

key

Scroll to the BASIC menu.

 

 

Press ENTER to access

BASIC

 

 

 

 

 

ADVANCED

 

Advanced level 2 parameters if

 

 

 

 

 

desired.

Press

 

 

 

 

 

key

Scroll to the ADVANCED menu.

 

 

Press ENTER to access

ADVANCED

 

 

 

 

 

PERMANENT STORE

 

Advanced level 2 parameters if

 

 

 

 

 

desired.

Press

 

 

 

 

 

key

Scroll to the PERMANENT

 

 

Press ENTER to access

PERMANENT STORE

 

 

 

STORE menu.

 

PASSWORD

 

Password parameter if desired.

 

 

 

 

 

 

Press

key

Scroll to the PASSWORD menu.

 

 

 

Press ENTER to access

PASSWORD

 

 

 

 

 

 

Password parameter if desired.

 

 

 

 

INPUTS

 

 

 

 

 

 

 

Press

key

Scroll to the INPUTS menu.

 

 

 

Press ENTER to access

INPUTS

 

 

 

 

 

 

Password parameter if desired.

 

 

 

 

OUTPUTS

 

 

 

 

 

 

 

Press ENTER key

Enter level 2 of inputs menu.

 

 

 

DIGITAL I/P 1

 

 

Press ENTER key

Enter level 3 of inputs menu.

 

 

 

 

 

 

 

MAP TO

 

 

 

 

 

 

52 PARAMETER

 

 

Press

key

Scroll to the 52 Parameter menu.

 

 

 

 

 

 

 

52 PARAMETER

 

 

 

 

 

 

BIT NUMBER

 

 

Press

key

Scroll to the Bit Number menu.

 

 

 

BIT NUMBER

 

 

 

 

 

 

POLARITY

 

 

Press ENTER key

Enter the Bit Number menu.

 

 

 

BIT NUMBER

 

 

 

 

 

 

01000000 MASK

 

 

Press OPTIMISE key

Allows you to change the value of

 

 

 

 

 

 

 

BIT NUMBER

 

 

 

 

the first bit.

 

01000000 MASK

 

 

 

 

 

 

 

 

Press OPTIMISE key

Allows you to change the value of

 

 

 

 

 

 

 

BIT NUMBER

 

 

 

 

the second bit.

 

01000000 MASK

 

 

 

 

 

 

 

 

Press OPTIMISE key

Allows you to change the value of

 

 

 

 

 

 

 

BIT NUMBER

 

 

 

 

the third bit.

 

01000000 MASK

 

 

 

 

 

 

 

 

Press

key

Allows you to change the value of

 

 

 

BIT NUMBER

 

 

 

 

the third bit.

 

01100000 MASK

 

 

 

 

 

 

 

 

Press ENTER key

Accept the change.

 

 

 

 

 

 

 

BIT NUMBER

 

 

 

 

 

 

01100000 MASK

 

 

Press # key several

Press the # key numerous times

 

 

 

System Status mode.

 

 

Stopped & Ready

 

times

 

to return to the system status

 

 

 

 

 

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MN850

Operation 3-5

Image 22
Contents Digital Soft-Start Table of Contents Appendix C Appendix aAppendix B Appendix DSection General Information Limited WarrantyIntroduction Safety Notice PrecautionsPhysical Location Section InstallationReceiving, Inspection and Storage Air Flow Clearance RequirementsCover Removal Mounting Instruction For tapped mounting holes Tools RequiredMounting Instructions For clearance mounting holes AC Main Circuit UL Required Fuses for Short Circuit Rating Connection DescriptionsCatalog Number Baldor Control SupplyMotor Overload and Thermal Protection Digital Soft-StartIn-Delta Soft-Start Connections Baldor DigitalNEC Wire Size and Protection Devices 45x20Two Wire Control Three Wire Control115 / 230VAC Top of Ramp Bypass Connection 115/230VACMotor Reversing Connection To AC InputInstallation Shock MountingOverview Pre-Start ChecklistSection Operation Sure to check the following itemsKeypad Operation Start-Up ProcedureKeypad Mode Switch System Program Menu Data Status Entry Action Description Display CommentsData Entry Mode System Status Mode Description Display CommentsMenu Mode Operating ModesMenu Structure Diagram Menu StructureMenu Navigation Examples Menu NavigationSave Param Motor Starting Key Terms Motor Starting Definitions TermApplications Auto Features Optimising Current Remote Start and Running the MotorMotor Stopping Definitions Term Stopping the MotorBasic Menu Section Parameter IndexMenu Descriptions Applications MenuParameter Index MN850 Advanced Menu Auto Features Menu Permanent Store Menu Password MenuInputs Menu Parameters Menu Outputs MenuTrips Menu Parameter Description Parameter Descriptions Title Parameter DescriptionRatedCurrent x P52 User Flags Definition Preset Value ExampleK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Power Off Checks Section TroubleshootingFault Trip Messages Preliminary ChecksTroubleshooting Guide Indication Corrective Action230/460VAC 3 Phase Relay and Contactor Coils Analog SignalsElectrical Noise Considerations Special Motor ConsiderationsSection Specifications and Product Data IdentificationStorage Conditions Input RatingsOperating Conditions 230V 460V 575V Mounting Dimensions Size10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix a CE Guidelines EMC Conformity and CE MarkingControl EMC Installation Instructions Cable Screens GroundingAppendix MN850 Title Parameter Adjustable Range Factory User Setting Appendix B Parameter ValuesApplications MN850 MN850 Applications B-3 Section General Information Appendix C Replacement Parts Voltage Independent Parts Description575VAC Parts Description Appendix D Voltage Surge Protection GroundingGrounded or Symbol High Resistance Ground Control Enclosure Voltage Surge Protection MN850Corner or Center-Tap Symbol Grounded Control Enclosure Table D-1 Baldor MOV SpecificationsVoltage Surge Protection MN850 Appendix E 500 Remote Keypad Mounting Template340 810 500 250 Baldor Electric Company  Baldor Electric Company MN850 03 C&J1500