Appendix B Parameter Values
Version 5MC (4/2/01)
Read Only Parameter Values
Title | P# | Parameter | Adjustable Range |
| Factory | User Setting |
|
|
|
|
|
|
|
Parameter | P0 | Dummy Parameter | 0 |
|
| |
|
|
|
|
|
|
|
| P1 | Station Number | 1 |
|
| |
|
|
|
|
|
| |
| P2 | Country | 44 (England) |
| ||
|
|
|
|
|
| |
| P3 | Software Type | Factory Set | Read Only |
| |
|
|
|
|
|
| |
| P4 | Software Version | Factory Set | Read Only |
| |
|
|
|
|
|
|
|
Password | P5 | Password Value | 0 |
|
| |
|
|
|
|
|
|
|
Advanced | P6 | Firing Mode | 0 |
|
| |
|
|
|
|
|
| |
Basic | P7 | Protection Mode | 192 (Full + Optimize) |
| ||
|
|
|
|
|
|
|
Parameters | P8 | Status 1 | 1 | (bit 00000001) |
| |
|
|
|
|
|
|
|
| P9 | Status 2 | 0 | (bit 00000000) |
| |
|
|
|
|
|
|
|
| P10 | Status 3 | 0 | (bit 0000000) |
| |
|
|
|
|
|
| |
Basic | P11 | Start Pedestal | 20 (% of line volts) |
| ||
|
|
|
|
|
|
|
| P12 | Start Time | 5 | (seconds) |
| |
|
|
|
|
|
| |
Advanced | P13 | Kick Pedestal | 75 (% of Line) |
| ||
|
|
|
|
|
| |
| P14 | Kick Time | 25 Cycles |
| ||
|
|
|
|
|
| |
| P15 | Dwell Time | 5 seconds |
| ||
|
|
|
|
|
| |
Basic | P16 | Stop Pedestal | 10 (% of Line) |
| ||
|
|
|
|
|
| |
| P17 | Stop Time | 0 seconds |
| ||
|
|
|
|
|
|
|
Auto Features | P18 | Auto Config. | 6 | (bit 00000110) |
| |
|
|
|
|
|
|
|
Advanced | P19 | Optimise Rate | 5 | (for unstable load) |
| |
|
|
|
|
|
| |
Parameters | P20 | Reference PF (Power Factor) | 146.7626 degrees |
| ||
|
|
|
|
|
| |
| P21 | Present PF (Power Factor) | 146.7626 degrees |
| ||
|
|
|
|
|
| |
| P22 | Delay Angle (SCR OFF time) | 146.7626 degrees |
| ||
|
|
|
|
|
| |
| P23 | Maximum Optimizing Delay | 57.55396 degrees |
| ||
|
|
|
|
|
| |
| P24 | Rated Current (High Byte | Factory Set | Factory Set |
| |
|
|
|
|
|
| |
| P25 | Rated Current (Low Byte – Units) | Factory Set | Factory Set |
| |
|
|
|
|
|
|
|
| P26 | Running Current Amps | 0 | Amps |
| |
|
|
|
|
|
|
|
| P27 | Peak Start Current (measured at last start) | 0 | Amps |
| |
|
|
|
|
|
| |
Advanced Current | P28 | Low Current Level (undercurrent trip) | 9.375% of running |
| ||
|
|
| Amps (P24 & P25) | Amps |
| |
|
|
|
|
|
| |
| P29 | Low Current Time (delay before trip) | 50 seconds |
| ||
|
|
|
|
|
| |
| P30 | Current Limit Level (scaling = 0.03125) | 350% of running |
| ||
|
|
|
| Amps |
| |
|
|
|
|
|
| |
| P31 | Current Limit Time (delay before trip) | 30 seconds |
| ||
|
|
|
|
|
| |
| P32 | Shearpin Level (undercurrent trip) | 3.125 x Ie Amps |
| ||
|
|
|
|
|
| |
| P33 | Shearpin Time (delay before trip) | 100 cycles |
| ||
|
|
|
|
|
| |
| P34 | Overload Level (SCR protection) | 1.09375 x Ie Amps |
| ||
|
|
|
|
|
| |
| P35 | Overload Delay (delay before trip) | 140 |
| ||
|
|
|
|
|
|
|
Note: (x Ie) means “Times the rated current of the control (P24 and P25 values).”
MN850 | Applications |