Baldor MN850, Baldor manual Section Specifications and Product Data, Identification

Page 46

Section 6

Specifications and Product Data

Identification

Three Phase Digital Soft–Start

MD 7 016 C B

Control Type

MD – Multipurpose Digital

Input Voltage

7- 208, 230, 460VAC

8- 230, 460, 575VAC

Ampere Rating

009- 9 Amp

016- 16 Amp

023- 23 Amp

030- 30 Amp

044- 44 Amp

059- 59 Amp

072- 72 Amp

085- 85 Amp

105- 105 Amp

146- 146 Amp

174- 174 Amp

202- 202 Amp

242- 242 Amp

300- 300 Amp

370- 370 Amp

500- 500 Amp

600- 600 Amp

750- 750 Amp

900- 900 Amp

1100- 1100 Amp

1200- 1200 Amp

Enclosure

A- Open Kit

B- Open Chassis (IP20)

C- NEMA12 (IP65)

P- Panel Mount

Note: Open Chassis meets NEMA Type 1 enclosure requirements but does not comply with UL Type 1 requirement for cable bending space.

Soft–Start Type

A- Combination controller with:

SInput circuit breaker

SInput contactor

SMotor overload

SMultipurpose Digital Soft–Start

B- Non–Combination controller with:

SInput contactor

SMotor overload

SMultipurpose Digital Soft–Start

C- Controller only

SMultipurpose Digital Soft–Start

MN850

Specifications and Product Data 6-1

Image 46
Contents Digital Soft-Start Table of Contents Appendix C Appendix aAppendix B Appendix DSection General Information Limited WarrantyIntroduction Safety Notice PrecautionsPhysical Location Section InstallationReceiving, Inspection and Storage Air Flow Clearance RequirementsCover Removal Mounting Instruction For tapped mounting holes Tools RequiredMounting Instructions For clearance mounting holes AC Main Circuit UL Required Fuses for Short Circuit Rating Connection DescriptionsCatalog Number Baldor Control SupplyMotor Overload and Thermal Protection Digital Soft-StartIn-Delta Soft-Start Connections Baldor DigitalNEC Wire Size and Protection Devices 45x20Two Wire Control Three Wire Control115 / 230VAC Top of Ramp Bypass Connection 115/230VACMotor Reversing Connection To AC InputInstallation Shock MountingOverview Pre-Start ChecklistSection Operation Sure to check the following itemsKeypad Operation Start-Up ProcedureKeypad Mode Switch System Program Menu Data Status Entry Action Description Display CommentsData Entry Mode System Status Mode Description Display CommentsMenu Mode Operating ModesMenu Structure Diagram Menu StructureMenu Navigation Examples Menu NavigationSave Param Motor Starting Key Terms Motor Starting Definitions TermApplications Auto Features Optimising Current Remote Start and Running the MotorMotor Stopping Definitions Term Stopping the MotorBasic Menu Section Parameter IndexMenu Descriptions Applications MenuParameter Index MN850 Advanced Menu Auto Features Menu Permanent Store Menu Password MenuInputs Menu Parameters Menu Outputs MenuTrips Menu Parameter Description Parameter Descriptions Title Parameter DescriptionRatedCurrent x P52 User Flags Definition Preset Value ExampleK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Power Off Checks Section TroubleshootingFault Trip Messages Preliminary ChecksTroubleshooting Guide Indication Corrective Action230/460VAC 3 Phase Relay and Contactor Coils Analog SignalsElectrical Noise Considerations Special Motor ConsiderationsSection Specifications and Product Data IdentificationStorage Conditions Input RatingsOperating Conditions 230V 460V 575V Mounting Dimensions Size10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 CE Declaration of Conformity Wiring of Shielded Screened CablesAppendix a CE Guidelines EMC Conformity and CE MarkingControl EMC Installation Instructions Cable Screens GroundingAppendix MN850 Title Parameter Adjustable Range Factory User Setting Appendix B Parameter ValuesApplications MN850 MN850 Applications B-3 Section General Information Appendix C Replacement Parts Voltage Independent Parts Description575VAC Parts Description Appendix D Voltage Surge Protection GroundingGrounded or Symbol High Resistance Ground Control Enclosure Voltage Surge Protection MN850Corner or Center-Tap Symbol Grounded Control Enclosure Table D-1 Baldor MOV SpecificationsVoltage Surge Protection MN850 Appendix E 500 Remote Keypad Mounting Template340 810 500 250 Baldor Electric Company  Baldor Electric Company MN850 03 C&J1500