Baldor Baldor, MN850 manual Section General Information

Page 61

Section 1

General Information

 

 

 

 

Read Only Parameter Values

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

P#

Parameter

 

 

Adjustable Range

Factory

User Setting

 

 

 

 

 

 

 

 

Parameters

P111

User Parameter

 

 

0–255

0

 

 

 

 

 

 

 

 

 

 

P112

Status 4

 

 

0–255

0 (bit 00000000)

 

 

 

 

 

 

 

 

 

 

P113

Drive Type

 

 

0–255

0

 

 

 

 

 

 

 

 

 

 

P114

Baud Rate

 

 

0–4

0

 

 

 

 

 

 

 

 

 

 

P115

Selected App

 

 

0–9

0

 

 

 

 

 

 

 

 

 

 

P116

5MC Inhibit Time (restart not allowed)

 

 

0–63.75 minutes

0 minutes

 

 

 

 

 

 

 

 

 

 

P117

Command Source

 

 

Unused

 

 

 

 

 

 

 

 

 

 

 

P118

Action On Bus Error

 

 

0–3

0

 

 

 

 

 

 

 

 

 

 

P119

Preset Parameter Number to Display

 

 

0.1–125

26 (parameter #)

 

 

 

 

 

 

 

 

 

 

P120

Status 5

 

 

0–255

0 (bit 00000000)

 

 

 

 

 

 

 

 

 

 

P121

User Flags 4

 

 

1–255

0 (bit 00000000)

 

 

 

 

 

 

 

 

 

 

P122

Soft–Start Smoothing

 

 

1–15

5 (for unstable load)

 

 

 

 

 

 

 

 

 

 

P123

Reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P124

Reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P125

Reserved for future use.

 

 

 

 

 

 

 

 

 

 

 

 

 

B-4 Applications

MN850

Image 61
Contents Digital Soft-Start Table of Contents Appendix B Appendix aAppendix C Appendix DSection General Information Limited WarrantyIntroduction Precautions Safety NoticeReceiving, Inspection and Storage Section InstallationPhysical Location Air Flow Clearance RequirementsCover Removal Mounting Instruction For tapped mounting holes Tools RequiredMounting Instructions For clearance mounting holes AC Main Circuit UL Required Fuses for Short Circuit Rating Connection DescriptionsCatalog Number Motor Overload and Thermal Protection Control SupplyBaldor Digital Soft-StartBaldor Digital In-Delta Soft-Start Connections45x20 NEC Wire Size and Protection DevicesTwo Wire Control Three Wire Control115 / 230VAC 115/230VAC Top of Ramp Bypass ConnectionTo AC Input Motor Reversing ConnectionShock Mounting InstallationSection Operation Pre-Start ChecklistOverview Sure to check the following itemsKeypad Mode Switch System Program Menu Data Status Entry Start-Up ProcedureKeypad Operation Action Description Display CommentsMenu Mode System Status Mode Description Display CommentsData Entry Mode Operating ModesMenu Structure Menu Structure DiagramMenu Navigation Menu Navigation ExamplesSave Param Motor Starting Definitions Term Motor Starting Key TermsApplications Auto Features Remote Start and Running the Motor Optimising CurrentStopping the Motor Motor Stopping Definitions TermMenu Descriptions Section Parameter IndexBasic Menu Applications MenuParameter Index MN850 Advanced Menu Auto Features Menu Permanent Store Menu Password MenuInputs Menu Parameters Menu Outputs MenuTrips Menu Parameter Description Title Parameter Description Parameter DescriptionsRatedCurrent x Example P52 User Flags Definition Preset ValueK3 BIT Mask Missing. Check fuses etc Second of a start request is forced to 0 stop time Thermal Switch 2 Over temp . Prevents re-start if set , Off Fault Trip Messages Section TroubleshootingPower Off Checks Preliminary ChecksIndication Corrective Action Troubleshooting Guide230/460VAC 3 Phase Electrical Noise Considerations Analog SignalsRelay and Contactor Coils Special Motor ConsiderationsIdentification Section Specifications and Product DataStorage Conditions Input RatingsOperating Conditions 230V 460V 575V Size Mounting Dimensions10.43 265 Mounting Dimensions 151 200 100 105 12.68 24.45 10.87 Specifications and Product Data MN850 Appendix a CE Guidelines Wiring of Shielded Screened CablesCE Declaration of Conformity EMC Conformity and CE MarkingControl Cable Screens Grounding EMC Installation InstructionsAppendix MN850 Appendix B Parameter Values Title Parameter Adjustable Range Factory User SettingApplications MN850 MN850 Applications B-3 Section General Information Voltage Independent Parts Description Appendix C Replacement Parts575VAC Parts Description Grounding Appendix D Voltage Surge ProtectionVoltage Surge Protection MN850 Grounded or Symbol High Resistance Ground Control EnclosureTable D-1 Baldor MOV Specifications Corner or Center-Tap Symbol Grounded Control EnclosureVoltage Surge Protection MN850 Appendix E 500 Remote Keypad Mounting Template340 810 500 250  Baldor Electric Company MN850 03 C&J1500 Baldor Electric Company