44 en Advanced FeaturesAutoDome 600 Series Analog PTZ Camera
7 | Advanced Features | ||
| This chapter details the advanced features of the VG5 AutoDome Camera. | ||
7.1 | Alarm Rules | ||
| The AutoDome features a powerful alarm rule engine. In its simplest form, an alarm rule | ||
| defines those inputs that activate specific outputs. In its more complex form, a rule can be | ||
| programmed to take any combination of inputs and keyboard commands to perform a dome | ||
| function. There are numerous combinations of alarm inputs and outputs that can be | ||
| programmed into twelve alarm rules. | ||
7.1.1 | Controlling Alarm Rules | ||
| The AUX 69 command allows a user to enable or disable all alarm rules. By default, alarm rules | ||
| are enabled until the | ||
| corresponding menu item for this command). Disabling alarms rules does not erase the rule, | ||
| the AutoDome preserves the | ||
| |||
| The | ||
| – | Disables all alarm rules | |
| – | Displays the message “Ack and Reset Alarms” if an | |
|
| when the AutoDome receives the disable command. You must acknowledge the alarm | |
|
| before the rule is disabled. | |
| – | Prevents the modification of an alarm rule while disabled. | |
7.1.2 | Alarm Rule Examples | ||
| Following are three examples for setting up alarm rules. The first example is a basic alarm | ||
| rule, and the second and third examples are more complex. | ||
| Example 1: Basic Alarm Rule | ||
| Scenario: We want a door alarm contact to: | ||
| 1. | Flash an OSD message (***ALARM 1***) on the display when the alarm is triggered. | |
| 2. | Move the AutoDome camera to a saved position. (For this example Shot 7.) | |
| 3. | Transmit a Bilinx signal over the coax cable to the headend system, such as an Allegiant, | |
|
| to trigger an alarm response. | |
| The sequence to program the above alarm rule example is as follows: | ||
| 1. | Wire the door contact to Input 1 in the AutoDome. This circuit is normally open. | |
| 2. | Define the Alarm Input(s) | |
|
| – From the Inputs Setup menu, ensure that Alarm Input 1 is set to N.O. (This is the | |
|
|
| default setting for Input 1.) |
|
| ||
| NOTICE! For instruction on wiring alarm and relay connections, see the VG5 AutoDome | ||
| Installation Manual. | ||
|
|
| |
| 3. | Define the Alarm Outputs from the Outputs Setup menu: | |
|
| a. | Ensure Output 5 is set to OSD. (This is the default setting for Output 5.) |
|
| b. Set Output 6 to Shot 7. | |
|
| c. | Set Output 7 to Transmit (a Bilinx signal to the head end). |
F.01U.270.005 2.0 2012.06 | User Manual | Bosch Security Systems, Inc. |