AutoDome 600 Series Analog PTZ CameraAdvanced Features en 53
7.8.2 | Displaying Azimuth, Elevation, and Compass Headings | ||||
|
| You can display only the azimuth/elevation readings or only the compass reading, or you can | |||
|
| display both readings at the same time. The AutoDome displays the azimuth/elevation | |||
|
| readings and the compass heading in the following way: | |||
|
| 180 / |
|
| |
|
| where: |
|
|
|
|
| – 180 is the Azimuth or the pan location in degrees. | |||
|
| – | |||
|
| – S is the compass direction (cardinal or intercardinal). | |||
|
| 1. Press | |||
|
| 2. Press | |||
|
| 3. Press | |||
|
| 4. Press | |||
7.9 | AutoHome Recalibration Commands and Settings | ||||
|
| The AutoHoming routine may be enabled for any site that is experiencing a large amount of | |||
|
| shifts in masks, prepositions, or playback tours. This feature adds the following AUX | |||
|
| commands to configure and to enable the AutoHome Recalibration feature: | |||
|
|
|
|
|
|
|
| Function | Command | Command | Description |
|
| Key | Number |
|
|
|
| On/Off | 680 | Homing Recalibration | Displays the current mode of operation, |
|
|
|
| Display | intervals, time until the next calibration, and |
|
|
|
|
| the number of recalibrations that have |
|
|
|
|
| occurred. |
|
|
|
|
| On – Turns display on. |
|
|
|
|
| Off – Turns off the display. |
|
| On/Off | 681 | Homing Recalibration | On – Enables recalibration (This action does |
|
|
|
|
| not cause the dome to |
|
|
|
|
| Off – Disables recalibration |
|
|
|
|
|
|
|
| On | 682 | Recalibration Mode | Each On command toggles the recalibration |
|
|
|
|
| mode as follows: |
|
|
|
|
| – Recalibrates only on the loss of home |
|
|
|
|
| position. |
|
|
|
|
| – Recalibrates on the loss of home and for |
|
|
|
|
| every periodic interval. |
|
| On/Off | 683 | Recalibration Interval | Changes the homing recalibration interval. |
|
|
|
|
| Intervals are in |
|
|
|
|
| hours. |
|
|
|
|
| Each On – increases interval by 6 hours |
|
|
|
|
| Each Off – decreases interval by 6 hours |
|
|
|
|
|
|
|
| On/Off | 684 | Initial Offset Time | Sets the initial offset time for the recalibration |
|
|
|
|
| interval. The offset time starts after the Homing |
|
|
|
|
| Calibration is enabled. The recalibration |
|
|
|
|
| interval begins its countdown after the offset |
|
|
|
|
| time. |
|
|
|
|
| Each On – increases offset time by 4 hours |
|
|
|
|
| Each Off – decreases offset time by 4 hours |
|
|
|
|
| Note: The offset time does not take effect until |
|
|
|
|
| the Homing Calibration is enabled. |
Bosch Security Systems, Inc. | User Manual | F.01U.270.005 2.0 2012.06 |