Bosch Appliances VG5 600 Alternative Control Protocols, Using an American Dynamics Controller

Page 29

AutoDome 600 Series Analog PTZ CameraAlternative Control Protocols en 29

4

Alternative Control Protocols

The VG5 AutoDome supports three alternative control protocols that allow a user to send commands and to receive information from the AutoDome. The VG5 AutoDome supports the following protocols:

Pelco-P

Pelco-D

American Dynamics (AD) Manchester

American Dynamics (AD) Sensormatic RS-422

The VG5 AutoDome natively supports the two Pelco protocols. To use the AD Manchester or the AD Sensormatic RS-422 protocol you must purchase a separate module. The module contains instructions to install any additional hardware and information about additional on- screen menus.

4.1

Setting FastAddress with Alternative Protocols

 

The VG5 AutoDome offers remote addressing via the FastAddress capability from a keyboard

 

that uses an alternative protocol. The FastAddress feature allows you to instal all domes first,

 

then set the addresses via the control system. Since it is not necessary to go to the camera’s

 

physical location, this feature makes it easier to readdress cameras at a later time.

4.1.1

Using an American Dynamics Controller

 

Prior to setting the FastAddress for each camera, all cameras will initially move together. After

 

the Unique Identifier is set, only the camera that was set with the FastAddress is capable of

sending and receiving commands. When setting the FastAddress, it is important to remember that some American Dynamics Manchester systems use address blocks of 1 to 64, while American Dynamics Sensormatic systems typically use address blocks of 1 to 99; meaning that when the controller/keyboard displays video for cameras higher than 64 or 99 the keyboard/controller sends a different control code to the camera (see Section A Appendix: FastAddress Conversions, page 64, for conversion charts). For example at Camera 65, the American Dynamics Manchester system sends out an address of 1, while the Sensormatic RS- 422 system with an address of 100 also sends out an address of 1.

It is NOT NECESSARY to convert these numbers with the Bosch FastAddress method. The camera automatically detects the address being transmitted by the Sensormatic RS-422 control system and adjusts the camera accordingly.

Bosch Security Systems, Inc.

User Manual

F.01U.270.005 2.0 2012.06

Image 29
Contents AutoDome 600 Series Analog PTZ Cam- era Page Table of Contents Keyboard Commands by Number Advanced Features Bosch Menu locked PTZ Setup unlocked Other MenusTroubleshooting Guide User Command Table Appendix FastAddress Conversions IndexGetting Started Powering OnEstablishing AutoDome Control For each of the system componentsLCD Keyboard CommandsBasic Keyboard Operation FastAddress Setting the Camera AddressTo set an address for a camera without an address To change or clear an address for a camera with an addressSpecial Passwords Setting PasswordsPassword Security Level To set or change a password locked commandTo open the main Setup Menu locked command Setup MenuSetup Menu On-Screen Display Menu NavigationCamera Setup Menu Auto ATWInternal OFFPAL Lens SetupExit Auto Focus Auto IrisSpot PTZ Setup MenuConstant FastNormal Momentary Display Setup MenuSector 1-16 Press Focus/Iris to blank or Edit Scene Title to accessPrivacy Masking Edit Sector TitleCommunication Setup Menu Alarm I/O Setup Inputs Setup Alarm I/O SetupInputs NoneOutputs Setup Outputs Setup MenuAlarm Relay OutputsRule Rule Setup MenuRule Setup None Language Menu Advanced Feature Setup MenuAdvanced Feature Setup Diagnostics Menu Bist 11.1 Alarm Status Submenu 2Setting Preset Shots Common AutoDome User Commands unlockedSetting AutoPan Mode Specifying a Shot or a Sector Title 4Configuring Preposition ToursTo start Preposition Tour To stop a Preposition Tour6Recording Tours 5Programming the Inactivity OperationAlternative Control Protocols Setting FastAddress with Alternative ProtocolsUsing an American Dynamics Controller Enter FastAddress Exit Command LockFastAddress Setting FastAddress with a Pelco Keyboard 2Using a Pelco ControllerNew Fast Address Saved Setup Menu Hardware Configuration Pelco Protocol ModeKeyboard Command User Action Description Pattern Pelco Keyboard CommandsAux On / Aux Off Aux OnPreset Command Description Special Preset CommandsPreset Initiates Preset TourPelco On-Screen Menus Bosch Menu locked Command Lock lockedPelco menu Bosch menu Setup Menu Camera Setup unlocked PTZ Setup unlockedPelco Camera Setup Menu provides access to camera settings OutdoorOther Menus Keyboard Commands by Number Zone Title Menu Enters Zone Title menu. Refer to Refer to .8 Azimuth, Elevation, Compass Directions, Locked Function Comm Command Description Key Alarm Rules Advanced FeaturesControlling Alarm Rules Alarm Rule ExamplesExample 2 Advanced Alarm Rule Click the Online Config button and then expand Alarm Example 3 Advanced Alarm Rule using AutoTrackClick Output Option Select Shot from the Type drop-down listOutput Option 6 Configuration AutoTrack Operation AutoTrack Settings and RecommendationsMount/Mounting Surface Stability AutoTrack OptimizationField of View Unwanted MotionVirtual Masking Setting AutoTrack Optimization ParametersPrivacy Masking Consistent Light ConditionsMotion Detection with Region of Interest Preset positions 90 throughImage Stabilization 7Pre-position TourAzimuth Range Compass Direction Setting the Azimuth Zero Point8Azimuth, Elevation, and Compass Directions Function Command Description Key Number AutoHome Recalibration Commands and SettingsDisplaying Azimuth, Elevation, and Compass Headings Readings and the compass heading in the following wayPreset or Recorded Tour Using the AutoHome RecalibrationSetting Values AutoHome Recalibration OperationIf O.K., then If using a non-Bosch power supply Troubleshooting GuideIf O.K., then If there is power to the AutoDome, then VG5 AutoDome Operation and ControlCannot access user If amber LED does not light when given PTZ commands, thenSettings No camera controlDoes not switch If O.K., then Automatically when Setting FastAddressWith an American Dynamics KeyboardOn monitor display Inside of OutdoorLow Voltage flashing Audio Connections with an VG5 600 Series AutoDome 2VG5 Series AutoDome AudioProblem Solution No Audio Poor Audio Problem Solution If O.K., thenUser Command Table AutoDome 600 Series Analog PTZ Camera User Command Table en Group Appendix FastAddress ConversionsBlock Numerics IndexCommand lock 36 Command Lock menu 37 commands Setup Custom tour PTZ En Index AutoDome 600 Series Analog PTZ Camera Page Page Page Bosch Security Systems, Inc