Sample: If there is video coming from Camera #131, look at the appropriate conversion table

 

below to convert the FastAddress accordingly (i.e. using an AD system 131=3 and using a

 

Sensormatic system 131=32). Ensure that the camera number displayed within the menu on

 

the keyboard represents the converted camera number.

BLOCK 1

 

BLOCK 2

Bosch

AD

 

Bosch

AD

1

1

 

65

1

2

2

 

66

2

3

3

 

67

3

4

4

 

68

4

5

5

 

69

5

6

6

 

70

6

7

7

 

71

7

8

8

 

72

8

9

9

 

73

9

10-64

10-64

 

74-

10-64

 

 

 

128

 

BLOCK 3

Bosch AD

1291

1302

1313

1324

1335

1346

1357

1368

1379

138- 10-64

BLOCK 4

Bosch AD

1931

1942

1953

1964

1975

1986

1997

2008

2019

202- 10-64

BLOCK 5

Bosch AD

2571

2582

2593

2604

2615

2626

2637

2648

2659

266- 10-64

BLOCK 6

 

BLOCK 7

 

BLOCK 8

Bosch

AD

 

Bosc

AD

 

Bosc

AD

 

 

 

h

 

 

h

 

321

1

 

385

1

 

449

1

322

2

 

386

2

 

450

2

323

3

 

387

3

 

451

3

324

4

 

388

4

 

452

4

325

5

 

389

5

 

453

5

326

6

 

390

6

 

454

6

327

7

 

391

7

 

455

7

328

8

 

392

8

 

456

8

329

9

 

393

9

 

457

9

330-

10-64

 

394-

10-64

 

458-

10-64

384

 

 

448

 

 

512

 

Table 1.1 Address Conversion Table for AD/Manchester Systems

Group 1

 

Group 2

IN

OUT

 

IN

OUT

1

1

 

100

1

2

2

 

101

2

3

3

 

102

3

4

4

 

103

4

5

5

 

104

5

6

6

 

105

6

7

7

 

106

7

8

8

 

107

8

9

9

 

108

9

10-99

10-99

 

109-

10-99

 

 

 

198

 

 

 

 

 

 

Group 3

IN

OUT

1991

2002

2013

2024

2035

2046

2057

2068

2079

208- 10-99

Group 4

 

Group 5

 

Group 6

 

Group 7

 

Group 8

IN

OUT

 

IN

OUT

 

IN

OUT

 

IN

OUT

 

IN

OUT

298

1

 

397

1

 

496

1

 

595

1

 

694

1

299

2

 

398

2

 

497

2

 

596

2

 

695

2

300

3

 

399

3

 

498

3

 

597

3

 

696

3

301

4

 

400

4

 

499

4

 

598

4

 

697

4

302

5

 

401

5

 

500

5

 

599

5

 

698

5

303

6

 

402

6

 

501

6

 

600

6

 

699

6

304

7

 

403

7

 

502

7

 

601

7

 

700

7

305

8

 

404

8

 

503

8

 

602

8

 

701

8

306

9

 

405

9

 

504

9

 

603

9

 

702

9

307-

10-99

 

406-

10-99

 

505-

10-99

 

604-

10-99

 

703-

10-99

396

 

 

495

 

 

594

 

 

693

 

 

792

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 1.2 Address Conversion Table for AD/Sensormatic RS-422 Systems

F.01U.270.005 2.0 2012.06

User Manual

Bosch Security Systems, Inc.

Image 64
Contents AutoDome 600 Series Analog PTZ Cam- era Page Table of Contents Bosch Menu locked PTZ Setup unlocked Other Menus Keyboard Commands by Number Advanced FeaturesTroubleshooting Guide User Command Table Appendix FastAddress Conversions IndexPowering On Getting StartedEstablishing AutoDome Control For each of the system componentsBasic Keyboard Operation Keyboard CommandsLCD Setting the Camera Address FastAddressTo set an address for a camera without an address To change or clear an address for a camera with an addressSetting Passwords Special PasswordsPassword Security Level To set or change a password locked commandSetup Menu To open the main Setup Menu locked commandSetup Menu On-Screen Display Menu NavigationCamera Setup Menu ATW AutoInternal OFFLens Setup PALExit Auto Focus Auto IrisPTZ Setup Menu SpotConstant FastNormal Display Setup Menu MomentaryEdit Scene Title to access Sector 1-16 Press Focus/Iris to blank orPrivacy Masking Edit Sector TitleCommunication Setup Menu Alarm I/O Setup Alarm I/O Setup Inputs SetupInputs NoneOutputs Setup Menu Outputs SetupAlarm Relay OutputsRule Setup Rule Setup MenuRule None Advanced Feature Setup Advanced Feature Setup MenuLanguage Menu Diagnostics Menu Bist 11.1 Alarm Status Submenu Setting AutoPan Mode Common AutoDome User Commands unlocked2Setting Preset Shots 4Configuring Preposition Tours Specifying a Shot or a Sector TitleTo start Preposition Tour To stop a Preposition Tour5Programming the Inactivity Operation 6Recording ToursUsing an American Dynamics Controller Setting FastAddress with Alternative ProtocolsAlternative Control Protocols Exit Command Lock Enter FastAddressFastAddress New Fast Address Saved Setup Menu 2Using a Pelco ControllerSetting FastAddress with a Pelco Keyboard Pelco Protocol Mode Hardware ConfigurationPelco Keyboard Commands Keyboard Command User Action Description PatternAux On / Aux Off Aux OnSpecial Preset Commands Preset Command DescriptionPreset Initiates Preset TourPelco On-Screen Menus Pelco menu Bosch menu Setup Menu Command Lock lockedBosch Menu locked PTZ Setup unlocked Camera Setup unlockedPelco Camera Setup Menu provides access to camera settings OutdoorOther Menus Keyboard Commands by Number Zone Title Menu Enters Zone Title menu. Refer to Refer to .8 Azimuth, Elevation, Compass Directions, Locked Function Comm Command Description Key Advanced Features Alarm RulesControlling Alarm Rules Alarm Rule ExamplesExample 2 Advanced Alarm Rule Example 3 Advanced Alarm Rule using AutoTrack Click the Online Config button and then expand AlarmClick Output Option Select Shot from the Type drop-down listOutput Option 6 Configuration AutoTrack Settings and Recommendations AutoTrack OperationAutoTrack Optimization Mount/Mounting Surface StabilityField of View Unwanted MotionSetting AutoTrack Optimization Parameters Virtual MaskingPrivacy Masking Consistent Light ConditionsPreset positions 90 through Motion Detection with Region of InterestImage Stabilization 7Pre-position Tour8Azimuth, Elevation, and Compass Directions Setting the Azimuth Zero PointAzimuth Range Compass Direction AutoHome Recalibration Commands and Settings Function Command Description Key NumberDisplaying Azimuth, Elevation, and Compass Headings Readings and the compass heading in the following wayUsing the AutoHome Recalibration Preset or Recorded TourSetting Values AutoHome Recalibration OperationTroubleshooting Guide If O.K., then If using a non-Bosch power supplyIf O.K., then If there is power to the AutoDome, then VG5 AutoDome Operation and ControlIf amber LED does not light when given PTZ commands, then Cannot access userSettings No camera controlSetting FastAddress Does not switch If O.K., then Automatically whenWith an American Dynamics KeyboardLow Voltage flashing Inside of OutdoorOn monitor display 2VG5 Series AutoDome Audio Audio Connections with an VG5 600 Series AutoDomeProblem Solution No Audio Problem Solution If O.K., then Poor AudioUser Command Table AutoDome 600 Series Analog PTZ Camera User Command Table en Block Appendix FastAddress ConversionsGroup Index NumericsCommand lock 36 Command Lock menu 37 commands Setup Custom tour PTZ En Index AutoDome 600 Series Analog PTZ Camera Page Page Page Bosch Security Systems, Inc