Panasonic WV-SP105E Image capture size, Transmission priority, Frame rate, Default 30fps

Page 21

Note:

When "On" is selected, only "Unicast port (AUTO)" will be available for "Transmission type".

When "On" is selected, it may take time to start dis- playing H.264 images.

When "On" is selected, H.264 images may not be displayed depending on the number of the concur- rent access user availability, etc.

When "On" is selected, only IPv4 access is avail- able.

When "On" is selected for either "H.264(1)" or

"H.264(2)", the maximum concurrent access num- ber is equal to or less than 10 users.

[Image capture size]

Select the image capture size from the following.

When "4:3" is selected for "Aspect ratio" H.264(1): QVGA/ VGA/ 1280 x 960*1 H.264(2): QVGA/ VGA

When "16:9" is selected for "Aspect ratio" H.264(1): 320x180/ 640x360/ 1280x720*1 H.264(2): 320x180/ 640x360

Default:

H.264(1): 1280x960*1

VGA*2

H.264(2): VGA

*1 SP105

*2 SP102

[Transmission priority]

Select "Constant bit rate" or "Frame rate" for the H.264 transmission mode.

Constant bit rate: H.264 images will be transmitted with the bit rate selected for "Max bit rate (per cli- ent)*".

Frame rate: H.264 images will be transmitted with the frame rate selected for "Frame rate*".

Default: Constant bit rate

Note:

When "Frame rate" is set for "Transmission priority", number of users who can access the camera may be limited more.

[Frame rate*]

Select a frame rate for H.264 images from the following. 1fps/ 3fps/ 5fps*/ 7.5fps*/ 10fps*/ 12fps* (PAL model)/ 15fps*/ 20fps*/ 30fps*

Default: 30fps*

Note:

When "Frame rate" is selected for "Transmission priority", this setting is available.

"Frame rate*" is synchronized with "Max bit rate

(per client)*". For this reason, the frame rate may be lower than the specified value when any value marked with an asterisk (*) is selected.

[Max bit rate (per client)*]

Select a H.264 bit rate per a client from the following. 64kbps/ 128kbps*/ 256kbps*/ 384kbps*/ 512kbps*/ 768kbps*/ 1024kbps*/ 1536kbps*/ 2048kbps*/ 3072kbps*/ 4096kbps*/ 8192kbps* SP105 / Unlimited*

Default:

H.264(1): 4096kbps*

 

SP105

1536kbps*

 

 

 

SP102

H.264(2): 1536kbps*

 

*"8192kbps*" is available only when the image cap- ture size is "1280x960" or "1280x720".

*"64kbps" and "128kbps" are available only when the image capture size is "QVGA", "VGA", "320x180", or "640x360".

*"Unlimited*" is available only when "Frame rate" is selected for "Transmission priority".

Note:

The H.264 bit rate is synchronized with "Bandwidth control(bit rate)" on the [Network] tab of "Network" page (page 45). For this reason, the bit rate may be lower than the value when any value with an asterisk (*) on the right is selected.

When "Unlimited*" is selected, the number of users who can access H.264 images will be limited to "1".

It is impossible to select "Unlimited*" for both

"H.264(1)" and "H.264(2)".

[Image quality]

Select the image quality of H.264 images from the fol- lowing.

Fine(Image quality priority)/ Normal/ Low(Motion prior- ity)

Default: Normal

21

Image 21
Contents Operating Instructions Model No. WV-SP105, WV-SP102 WV-SP105E, WV-SP102EContents About notations PrefaceTrademarks and registered trademarks AbbreviationsViewer software Example of IPv6 access Example of IPv4 accessMonitor images on a PC Monitor images from a single cameraRefresh interval of Jpeg images About the Live Zoom buttons Alarm occurrence indication button*2Brightness buttons*2 + brighter button Image will be brighter Camera titleMonitor images from multiple cameras Alarm type Action at an alarm occurrenceAction at an alarm occurrence Notify of alarm occurrences by e-mailTransmit images onto an FTP server Equipped security functions About the network securityHow to display the setup menu Display the setup menu from a PCHow to operate the setup menu About the setup menu window 4Setup 1Maintenance button0Schedule button 2Help buttonConfigure the basic settings Basic Default On Power indicator green Default On Link/Access indicatorLink indicator orange Access indicator GreenDefault 1280x960*1 Configure the settings relating to Jpeg images JPEG/H.264Aspect ratio Refresh interval Jpeg264 1 · H.264 Configure the settings relating to H.264 images JPEG/H.264Default Normal Default 30fpsImage capture size Transmission priorityAvailable value 1 Default Default Multicast TTL/HOPLimit*2Refresh interval Transmission typeImage adjust Extra zoom SP105Privacy zone Default Off Mask area Adaptive black stretchBack light compensationBLC Default OnHigh Auto slow shutter Light control modeSimple black & white mode Default Off White balanceDefault Blue gain Default ATW1Default High Chroma gain level Default Pedestal levelSet mask areas Extra zoom Reset button+ button − buttonDefault Off Setup button AreaDisplay type IP address Example of entryAvailable number of characters 1 128 characters Configure the alarm settings Alarm Configure the settings relating to the alarm action AlarmAlarm Alarm image Configure the settings relating to the alarm image AlarmConfigure the VMD settings VMD area VMD information addition Light detection controlInformation addition Set the VMD areas VMD area Destination of notification Mail notificationPanasonic alarm protocol Panasonic alarm protocol notificationAvailable range 1 Default Retry times Destination portAccess level Password Retype passwordUser auth Available number of characters 4 32 charactersDefault Off IP address Host checkHost auth Priority stream Default 1280×960*1 VGA*2Activation Destination IP addressConfigure the settings relating to the mail server Mail Configure the settings relating to the FTP server FTP Time adjustment Configure the settings relating to the NTP server NTPDefault Time adjustment interval Default 1hConfigure the network settings Network Configure the network settings NetworkIPv4 network Common IPv6 networkDefault 20min Easy IP Setup accommodate periodDefault Off Host name Configure the settings relating to Ddns DdnsAccess interval Available number of characters 1 64 charactersConfigure the settings relating to Snmp Snmp Default 1s Default Off Directory nameFTP periodic image transmission FTP periodic image transmissionHow to set the schedules How to delete the set schedule Configure the settings relating to the schedules Schedule Error description Maintenance of the camera MaintenanceCheck the system log System log Time & dateUpgrade the firmware Upgrade Reset the settings/Reboot the camera Default reset Reset to the default and load the default Html filesReboot Displaying the Help screen Viewing HelpCategory Indication Description About the displayed system logError indications relating to login Error indications relating to DdnsTroubleshooting Cannot access from the webBrowser No image is displayed No indicator lights Alarm occurrence indicationImage is not being refreshed No image is displayed or tooWhen displaying H.264 images Played on the information bar Following message is disPop-up blocked. To see this Pop-up or additional optionsPanasonic Canada Inc