MAINTENANCE AND TROUBLESHOOTING
Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the reed switch should be adjusted.
to the console, keep liquids away from the console and keep the console out of direct sunlight.
HEART RATE MONITOR TROUBLESHOOTING
If the console does not turn on, make sure that the power cord is fully plugged in. If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 27 and adjust the contrast level of the display.
If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the dis-
To adjust the reed switch, first unplug the power cord. Using a flat screwdriver, release the tabs on the Top Cover
(20)and pry the Top Cover upward off the elliptical.
20 |
played heart rate appears to be too high or too low, see step 5 on page 21.
HOW TO CALIBRATE THE RAMP
If the ramp is not functioning properly, the ramp may need to be calibrated. To calibrate the ramp, press and hold the Calorie button for several seconds until the test mode appears in the display.
Press the Calorie button again. Press the 1 Step Ramp increase or decrease button to calibrate the ramp. The ramp will move upward and downward as it calibrates.
When the ramp stops moving, the ramp is calibrated. Then, press the Calorie button repeatedly to exit the test mode.
Next, look into the access opening and locate the Reed Switch (69). Rotate the Large Pulley (74) until a Magnet (75) is aligned with the Reed Switch.
93 75 | 74 |
69 |
|
Next, loosen, but do not remove, the indicated M4 x 16mm Screw (93). Slide the Reed Switch (69) slightly toward or away from the Magnet (75). Then, retighten the M4 x 16mm Screw.
Plug in the power cord and rotate the large pulley for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the access cover.