Operation of the Xanbus AGS
Using Quiet Time
Use the Quiet Time feature to ensure that the AGS will not start the generator during the night or during times that conflict with local noise restrictions.
Using Quiet Time involves three steps.
1."QT En" must be set to [Enabled]. The default setting is [Enabled].
2."QT Begin" must have an appropriate time set for Quiet Time to start on schedule. The default setting for "QT Begin" is [9:00 PM] or 21:00 if using a
3."QT End" must have an appropriate time set for Quiet Time to stop on schedule. The default setting for "QT End" is [8:00 AM] or 8:00 on the
For more information about Quiet Time settings, see “QT En” on page 40, “QT Begin” on page 41, and “QT End” on page 42.
To enable Quiet Time:
1.On the Auto Gen Start menu, use the arrow buttons to highlight "QT En".
2.Press Enter.
3.Use the arrow buttons to select [Enabled].
4.Press Enter.
To set the beginning of Quiet Time:
1.On the Auto Gen Start menu, use the arrow buttons to highlight "QT Begin", then press Enter.
2.Use the arrow buttons to select the hour, then press Enter.
3.Use the arrow buttons to select the minutes, then press Enter. If the
4.Use the arrow buttons to select AM or PM, then press Enter.
5.Press Exit twice to return to the System Home screen.
To set the end of Quiet Time:
FSW System Home Screen
System Status
Battery | 20.4A | 53.9V | |
BatLev |
|
| |
Load |
|
| 1235W |
AC1 | 1150W | 3202V |
Menu
Select Device Menu |
| AGS Menu | Set Quiet Time settings | ||||||
|
|
|
|
|
|
|
|
| |
Select Device |
|
| XAGS 00: Setup |
|
| XAGS 00: Adv |
| ||
System Settings |
|
| Advanced Settings |
|
| QT En | [Enabled] | ||
FSW3012 |
|
| GenMode | [ManualOff] |
|
| QT Begin | [10:00AM] | |
EMS |
|
| Clear Faults Warnings |
|
| QT End | [7:00AM] | ||
XAGS |
|
|
| View Device Info |
|
| Gen Type | [2] | |
|
|
|
|
|
|
|
|
|
|
1. | On the Auto Gen Start menu, use the arrow buttons to highlight "QT |
| End", then press Enter. |
2. | Use the arrow buttons to select the hour, then press Enter. |
3. | Use the arrow buttons to select the minute, then press Enter. |
| If the |
4. | Use the arrow buttons to select AM or PM, then press Enter. |
Figure 35 Using the Quiet Time Feature
5. Press Exit twice to return to the System screen. |
66 | Xanbus Automatic Generator Start (AGS) Owner’s Guide |