Xantrex Technology 809-0915 manual Type, Relay Function Preset Configuration Setting

Page 25

Xanbus Automatic Generator Start Installation

Type 1

Type 1 is a three-wire GlowStop configuration recommended for “three- wire” generators with glow plugs that need to be operated before a start is attempted.

AGS Harness W ires

Generator W ires

Relay Function

Preset Configuration Setting

 

 

Crank retry time

30 s

 

 

Gen Cool Down

30 s

 

 

Gen Spin Down

3 s

 

 

Shutdown bypass time

0 s

Relay 1

Relay 2

12

13

14

16

17

18

GENERATOR RUN SIGNAL GENERATOR RUN SIGNAL RETURN

5A fuse

PREHEAT/STOP

5A fuse

START

Start tries

3

For additional information, see “Circuit Limitations” on page 11.

Figure 7 Type 1 Connection Diagram

Relay Function

Preset Configuration Setting

 

 

 

 

Relay 1 mode

GlowStop

 

Relay 3 mode

No function

 

 

 

 

Gen Run signal hold time

0.5 s

 

 

 

 

Preheat time

20 s

 

 

 

 

Preheat to crank delay

1 s

 

 

 

 

Crank time

15 s

 

 

 

 

 

 

 

975-0082-01-01

15

Image 25
Contents Xanbus Automatic Generator Start AGS Page Exclusion for Documentation TrademarksDate and Revision Document Part NumberPurpose About This GuideScope AudienceRelated Information Reference Important Safety InstructionsRestrictions on USE FCC Information to the UserPage Contents Page Xanbus Automatic Generator Start AGS Basic Function IntroductionSystem Requirements Functions AGS unit Material ListXanbus-Enabled Products and Accessories Front panel features FeaturesXanbus Bottom panel featuresMaterials and Tools Required Xanbus Automatic Generator Start InstallationChoosing a Location Shock and Energy Hazards Routing ConnectionsMounting the Unit Installation OverviewCircuit Parameter Circuit Maximum Wiring to the 20-contact ConnectorFt m Over 30 ft m To install the AGS using the wiring harnessXanbus Automatic Generator Start Installation Connecting the Generator Type Relay Function Preset Configuration SettingType 2 Connection Diagram Type 3 Connection Diagram Type 4 Connection Diagram Relay Function Type 5 Connection DiagramType 6 Connection Diagram Type 7 Connection Diagram two-wire Type 8 Connection Diagram two-wire Type 9 Connection Diagram Type 10 Connection Diagram Type 11 Connection Diagram Type 12 Connection Diagram Type 13 Connection Diagram Type 14 Connection Diagram two-wire Wire Connecting the Thermostats optionalNumber Function Wire Color Connecting an External Shutdown optional Connecting an External Manual ON/OFF Switch optionalWire Wiring Harness Number Function Wire Color Connecting an External ON/OFF LEDExternal ON/OFF Switch and LED Wiring Diagram To connect the wiring harness to the AGS Connecting the Wiring Harness to the AGSConnecting the AGS to the Xanbus Network Connecting the Xanbus System Control Panel SCP Verifying Power Is AvailableOverview Configuration of the Xanbus AGSTo change operational settings on the AGS Menu Accessing the AGS MenuXanbus Automatic Generator Start AGS Menu Xanbus AGS Menu To configureAGS Configuration Menu Contents QT En Configuration MenuValue Description QT Begin Gen Type QT EndDescription Cfg Trigger Start DCV 30 sec Values DefaultStart DCV 15 min Start DCV 24 hr Start DCV 2 hrStop Absorb Stop FloatStop Temp2 Temp1Load Value DefaultStart Load Stop Load Starter Cool Down Cfg GenGen Spin Down Gen Cool DownExercise Per Max Run TimeExercise Time Exercise DurGen Run Hold Time Relay3Crank Time Crank DelayCrank Retry Time Preheat TimeGen Start Tries Automatic Mode Restore DefaultsGenMode Manual Off Mode Manual On ModeMode View Fault LogView Device Info View Event LogItems User SettingsOperation of the Xanbus AGS Accessing the AGS Home ScreenTo start the generator manually Starting and Stopping the GeneratorTo enable Quiet Time Using Quiet TimeModes of Operation Putting the AGS in Standby ModeTo return the AGS to Operating Mode Returning the AGS to Operating ModeTo view a message from a fault list or warning list TroubleshootingTroubleshooting AGS Warning Messages AGS Fault Messages Fault Reference TableElectrical Specifications SpecificationsEnvironmental Specifications Regulatory ApprovalsDimensions Weight Mounting Connectors Physical SpecificationsWarranty Warranty and Return InformationDisclaimer Warranty and Return InformationReturn Procedure Return Material Authorization PolicyInformation About Your System Appendix a Generator Auto Start Requirements and Types Recommended FeaturesGenerator Starting Types Three-Wire Onan Two WireThree-Wire Automotive RunMode Appendix B Relay TimingMomentaryRun Mode Timing Diagram MomentaryRun ModeGlowStop Mode Timing Diagram GlowStop ModeStartStop Mode Timing Diagram StartStop ModePulseStop Mode Timing Diagram PulseStop ModePulseStop Mode Relay 1 Behavior Page Page Xantrex Technology USA Inc