Configuration of the Xanbus AGS
Temp1
Full name Thermostat 1
Purpose The "Temp1" trigger enables the generator to start in response to a signal from a thermostat. With "Temp1" set to [Enabled], the AGS will start the generator to help power the item controlled by that thermostat.
Temp2
Full name Thermostat 2
Purpose "Temp2" is intended to be used when the AGS is connected to a second thermostat. All information and procedures for "Temp1" also apply for "Temp2".
Values | Default |
| Values | Default |
|
|
|
|
|
Disabled, Enabled | Disabled |
| Disabled, Enabled | Disabled |
|
|
|
|
|
When to use Enable "Temp1" if a thermostat is available that controls a component that has a
Considerations If "Temp1" is enabled, the generator will start in response to a signal from the thermostat. Everything related to setting the thermostat must be done on the thermostat. For example: setting the temperature at which the furnace or air conditioning system comes on must be done on the thermostat. There are no thermostat temperature settings on the AGS or the Xanbus System Control Panel (SCP).
If "Temp1" is disabled, the component connected to that thermostat will require that the generator be started manually in order for that component to have power. Otherwise, the component will need to be connected to another AC input source.