Configuration of the Xanbus AGS
Table 4 Generator Type Descriptions
| Description |
|
|
|
|
Option | Mode | For Technical Details, see.a |
|
|
|
Type 12 | GlowStop with no preheat | page 26 |
|
|
|
Type 13 | PulseStop with Relay 3 preheat | page 27 |
|
|
|
Type 14 | Run with no preheat and no switched B+ | page 28 |
| requirement |
|
|
|
|
a.See “Appendix B: Relay Timing” on page 82 for additional information.
When to use Use this setting after installing the AGS hardware. Selecting a suitable "Gen Type" automatically configures the AGS to work with the ignition system and starting requirements of the generator. Consult the generator manual or contact the generator’s manufacturer for specific generator starting requirements.
Outcomes Selecting a "Gen Type" from the list automatically configures the following settings:
•Preheat time
•Preheat end to crank delay time
•Crank time
•Crank retry time
•Starter cool down time
•Generator cool down
•Generator spin down time
•Generator run signal hold time
•Start tries.
If the presets will not work with the desired generator, it may be necessary to manually configure some of the settings listed above using information from the generator manufacturer. These settings can be changed in the CfgGen Menu on page 53.