Xantrex Technology 809-0915 manual Description

Page 53

Configuration of the Xanbus AGS

Table 4 Generator Type Descriptions

 

Description

 

 

 

 

Option

Mode

For Technical Details, see.a

 

 

 

Type 12

GlowStop with no preheat

page 26

 

 

 

Type 13

PulseStop with Relay 3 preheat

page 27

 

 

 

Type 14

Run with no preheat and no switched B+

page 28

 

requirement

 

 

 

 

a.See “Appendix B: Relay Timing” on page 82 for additional information.

When to use Use this setting after installing the AGS hardware. Selecting a suitable "Gen Type" automatically configures the AGS to work with the ignition system and starting requirements of the generator. Consult the generator manual or contact the generator’s manufacturer for specific generator starting requirements.

Outcomes Selecting a "Gen Type" from the list automatically configures the following settings:

Preheat time

Preheat end to crank delay time

Crank time

Crank retry time

Starter cool down time

Generator cool down

Generator spin down time

Generator run signal hold time

Start tries.

If the presets will not work with the desired generator, it may be necessary to manually configure some of the settings listed above using information from the generator manufacturer. These settings can be changed in the CfgGen Menu on page 53.

975-0082-01-01

43

Image 53
Contents Xanbus Automatic Generator Start AGS Page Exclusion for Documentation TrademarksDate and Revision Document Part NumberPurpose About This GuideScope AudienceRelated Information Reference Important Safety InstructionsRestrictions on USE FCC Information to the UserPage Contents Page Xanbus Automatic Generator Start AGS Basic Function IntroductionSystem Requirements Functions AGS unit Material ListXanbus-Enabled Products and Accessories Front panel features FeaturesXanbus Bottom panel featuresChoosing a Location Xanbus Automatic Generator Start InstallationMaterials and Tools Required Shock and Energy Hazards Routing ConnectionsMounting the Unit Installation OverviewCircuit Parameter Circuit Maximum Wiring to the 20-contact ConnectorFt m Over 30 ft m To install the AGS using the wiring harnessXanbus Automatic Generator Start Installation Connecting the Generator Type Relay Function Preset Configuration SettingType 2 Connection Diagram Type 3 Connection Diagram Type 4 Connection Diagram Relay Function Type 5 Connection DiagramType 6 Connection Diagram Type 7 Connection Diagram two-wire Type 8 Connection Diagram two-wire Type 9 Connection Diagram Type 10 Connection Diagram Type 11 Connection Diagram Type 12 Connection Diagram Type 13 Connection Diagram Type 14 Connection Diagram two-wire Number Function Wire Color Connecting the Thermostats optionalWire Connecting an External Shutdown optional Connecting an External Manual ON/OFF Switch optionalWire Wiring Harness Number Function Wire Color Connecting an External ON/OFF LEDExternal ON/OFF Switch and LED Wiring Diagram To connect the wiring harness to the AGS Connecting the Wiring Harness to the AGSConnecting the AGS to the Xanbus Network Connecting the Xanbus System Control Panel SCP Verifying Power Is AvailableOverview Configuration of the Xanbus AGSTo change operational settings on the AGS Menu Accessing the AGS MenuXanbus Automatic Generator Start AGS Menu Xanbus AGS Menu To configureAGS Configuration Menu Contents Value Description Configuration MenuQT En QT Begin Gen Type QT EndDescription Cfg Trigger Start DCV 30 sec Values DefaultStart DCV 15 min Start DCV 24 hr Start DCV 2 hrStop Absorb Stop FloatStop Temp2 Temp1Start Load Value DefaultLoad Stop Load Starter Cool Down Cfg GenGen Spin Down Gen Cool DownExercise Per Max Run TimeExercise Time Exercise DurGen Run Hold Time Relay3Crank Time Crank DelayCrank Retry Time Preheat TimeGen Start Tries GenMode Restore DefaultsAutomatic Mode Manual Off Mode Manual On ModeMode View Fault LogView Device Info View Event LogItems User SettingsOperation of the Xanbus AGS Accessing the AGS Home ScreenTo start the generator manually Starting and Stopping the GeneratorTo enable Quiet Time Using Quiet TimeModes of Operation Putting the AGS in Standby ModeTo return the AGS to Operating Mode Returning the AGS to Operating ModeTo view a message from a fault list or warning list TroubleshootingTroubleshooting AGS Warning Messages AGS Fault Messages Fault Reference TableElectrical Specifications SpecificationsEnvironmental Specifications Regulatory ApprovalsDimensions Weight Mounting Connectors Physical SpecificationsWarranty Warranty and Return InformationDisclaimer Warranty and Return InformationReturn Procedure Return Material Authorization PolicyInformation About Your System Generator Starting Types Recommended FeaturesAppendix a Generator Auto Start Requirements and Types Three-Wire Onan Two WireThree-Wire Automotive RunMode Appendix B Relay TimingMomentaryRun Mode Timing Diagram MomentaryRun ModeGlowStop Mode Timing Diagram GlowStop ModeStartStop Mode Timing Diagram StartStop ModePulseStop Mode Timing Diagram PulseStop ModePulseStop Mode Relay 1 Behavior Page Page Xantrex Technology USA Inc