Xantrex Technology 809-0915 manual Ft m Over 30 ft m, To install the AGS using the wiring harness

Page 22

Xanbus Automatic Generator Start Installation

To install the AGS using the wiring harness:

1.Connect each wire on the harness to its intended wire or contact on the generator, thermostats, or external switches. Tape, or otherwise secure, the unused wires to ensure they do not make unintended connections.

2.Plug the harness into the connector on the bottom panel of the AGS.

Wire Identification Each wire on the harness is identified by a number and a color. The wire numbers are shown in Figure 6 and their colors and functions are described in the next table.

Wire Size and Length Required wire sizes for the external connections to the wiring harness are:

0–30 ft. (9 m)

Over 30 ft. (9 m)

 

 

18 AWG

16 AWG

 

 

When planning the routing for external connections, ensure that wire lengths are sufficient to plug the wiring harness into the AGS once all the external connections are complete.

To generator, thermostats, and external switches

To 20-contact connector on AGS

Figure 6 AGS Wiring Harness

Wire

 

Wiring Harness

Number

Function

Wire Color

 

 

 

1

Thermostat 1 input

Yellow

2

Thermostat 1 return

Gray

3

Thermostat 2 input

Orange

4

Thermostat 2 return

Gray

5

External shutdown input

White/Black

6

External shutdown return

Gray

7

External manual on input

White/Green

8

External manual off input

White/Red

9

External ON/OFF LED Indicator output

White/Blue

10

Constant 12/24 V B+ (battery positive) for External ON/

Red

 

OFF/LED Indicator

 

 

 

 

12

Xanbus Automatic Generator Start (AGS) Owner’s Guide

Image 22
Contents Xanbus Automatic Generator Start AGS Page Date and Revision TrademarksExclusion for Documentation Document Part NumberScope About This GuidePurpose AudienceRelated Information Important Safety Instructions ReferenceFCC Information to the User Restrictions on USEPage Contents Page Introduction Xanbus Automatic Generator Start AGS Basic FunctionSystem Requirements Functions Material List AGS unitXanbus-Enabled Products and Accessories Features Front panel featuresBottom panel features XanbusMaterials and Tools Required Xanbus Automatic Generator Start InstallationChoosing a Location Routing Connections Shock and Energy HazardsInstallation Overview Mounting the UnitWiring to the 20-contact Connector Circuit Parameter Circuit MaximumTo install the AGS using the wiring harness Ft m Over 30 ft mXanbus Automatic Generator Start Installation Connecting the Generator Relay Function Preset Configuration Setting TypeType 2 Connection Diagram Type 3 Connection Diagram Type 4 Connection Diagram Type 5 Connection Diagram Relay FunctionType 6 Connection Diagram Type 7 Connection Diagram two-wire Type 8 Connection Diagram two-wire Type 9 Connection Diagram Type 10 Connection Diagram Type 11 Connection Diagram Type 12 Connection Diagram Type 13 Connection Diagram Type 14 Connection Diagram two-wire Wire Connecting the Thermostats optionalNumber Function Wire Color Connecting an External Manual ON/OFF Switch optional Connecting an External Shutdown optionalConnecting an External ON/OFF LED Wire Wiring Harness Number Function Wire ColorExternal ON/OFF Switch and LED Wiring Diagram Connecting the Wiring Harness to the AGS To connect the wiring harness to the AGSConnecting the AGS to the Xanbus Network Verifying Power Is Available Connecting the Xanbus System Control Panel SCPConfiguration of the Xanbus AGS OverviewAccessing the AGS Menu To change operational settings on the AGS MenuXanbus AGS Menu To configure Xanbus Automatic Generator Start AGS MenuAGS Configuration Menu Contents QT En Configuration MenuValue Description QT Begin QT End Gen TypeDescription Cfg Trigger Values Default Start DCV 30 secStart DCV 15 min Start DCV 2 hr Start DCV 24 hrStop Float Stop AbsorbStop Temp1 Temp2Load Value DefaultStart Load Stop Load Cfg Gen Starter Cool DownGen Cool Down Gen Spin DownMax Run Time Exercise PerExercise Dur Exercise TimeRelay3 Gen Run Hold TimeCrank Retry Time Crank DelayCrank Time Preheat TimeGen Start Tries Automatic Mode Restore DefaultsGenMode Manual On Mode Manual Off ModeView Device Info View Fault LogMode View Event LogUser Settings ItemsAccessing the AGS Home Screen Operation of the Xanbus AGSStarting and Stopping the Generator To start the generator manuallyUsing Quiet Time To enable Quiet TimePutting the AGS in Standby Mode Modes of OperationReturning the AGS to Operating Mode To return the AGS to Operating ModeTroubleshooting To view a message from a fault list or warning listTroubleshooting AGS Warning Messages Fault Reference Table AGS Fault MessagesEnvironmental Specifications SpecificationsElectrical Specifications Regulatory ApprovalsPhysical Specifications Dimensions Weight Mounting ConnectorsWarranty and Return Information WarrantyWarranty and Return Information DisclaimerReturn Material Authorization Policy Return ProcedureInformation About Your System Appendix a Generator Auto Start Requirements and Types Recommended FeaturesGenerator Starting Types Two Wire Three-Wire OnanThree-Wire Automotive Appendix B Relay Timing RunModeMomentaryRun Mode MomentaryRun Mode Timing DiagramGlowStop Mode GlowStop Mode Timing DiagramStartStop Mode StartStop Mode Timing DiagramPulseStop Mode PulseStop Mode Timing DiagramPulseStop Mode Relay 1 Behavior Page Page Xantrex Technology USA Inc