GAS LEAK TESTING | 15 |
Check for leaks by wetting the connections with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
CHECK SIDE BURNER COMPONENT
Check:
1)Side burner lines to valve connections.
2)Side burner line to side burner orifice.
3)Side burner hose to side burner bulkhead.
WARNING: If there is a leak at connection (1, 2 or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re- tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL OR SIDE BURNER. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.
CHECK GAS SUPPLY CONNECTIONS
Check:
4)Corrugated gas
5)Regulator hose to bulkhead.
1
1 |
2
WARNING: If there is a leak at connection (4 or 5), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after
Log onto www.weber.com®.
Check:
6)Regulator to cylinder.
7)The
WARNING: If there is a leak at connections (6 or 7), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.
Log onto www.weber.com®.
When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.
3 |
4
5
67
WWW.WEBER.COM®