| 18 | OPERATING INSTRUCTIONS | 
MANUALLY LIGHTING THE SIDE BURNER
DANGER
Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive 
| 1) Remove the Side Burner lid by pushing down slightly on either end. | 2 | |
| 2) Check that the side burner valves are turned OFF. (Push knobs in and turn | 
 | |
| clockwise to ensure that they are in the off position.) | 
 | |
| WARNING: | 
 | |
| The burner control knobs must be in the OFF position before | 1 | |
| turning on the liquid propane cylinder valve. If they are not | ||
| 
 | ||
| in the OFF position, when you turn on the LP cylinder valve, | 
 | |
| the “excess gas flow control” feature will activate, limiting | 
 | |
| the flow of gas from the LP cylinder. If this should occur, turn | 
 | |
| OFF the LP tank valve and burner control knobs. Then start | 
 | |
| over. | 
 | 
3)Turn the LP tank valve on (turn 
4)Put match in a match holder and strike match.
5)Push in and turn the side burner control knob ( 1 - rear) or control knob ( 2 - front) to START/HI.
6)Hold match holder and lit match by right side of side burner.
CAUTION: Side burner flame may be difficult to see on a bright sunny day.
WARNING: If the side burner does not light:
1)Turn OFF the side burner control valve.
2)Wait 5 minutes to let the gas clear before you try again or try to light with a match.
46
2 5
WWW.WEBER.COM®