3-5 Display Symbols and Key Operation

Key operation

Key operation affects how the balance functions. The basic key operations are:

“Press and release the key immediately” or “Press the key” = normal key operation during measurement

“Press and hold the key”

Display symbols

Each key, when pressed or when pressed and held, functions as follows:

Key

When pressed

When pressed and held

 

 

 

Turns the display on or off. The standby indicator is displayed when the display is turned off. The weighing mode is enabled when the display is turned on.

This key is available anytime. Pressing the key during operation will interrupt the operation and turn the display off.

 

 

In the weighing mode, turns the minimum

Enters the function table mode.

 

 

weighing value on or off.

Refer to

“9. FUNCTION TABLE”.

 

 

In the counting or percent mode, enters

 

 

 

 

the sample storing mode.

 

 

 

 

 

 

 

 

Switches the weighing units stored in the

Enters the response adjustment mode.

 

 

function table.

 

 

 

 

Refer to “4. WEIGHING UNITS”.

 

 

 

 

 

 

 

 

Cancels the operation when performing

Enters the calibration mode.

 

 

settings.

 

 

 

 

 

 

 

 

Outputs the weight data to a printer or

No function at the factory setting

 

 

personal computer using the RS-232C

By changing the function table:

 

 

serial interface, depending on the

 

 

Outputs

“Title block” and “End block” for

 

 

function table settings.

 

 

GLP report.

 

 

 

 

 

Confirms the operation when performing

 

 

 

 

settings.

 

 

 

 

 

 

 

 

 

Sets the display to zero.

 

 

 

 

 

 

8

Image 10
Contents RI S WM+PD4001199Page Contents Connection to Peripheral Equipment MaintenanceRS-232C Serial Interface External Dimens IonsAbout This Manual FeaturesIntroduction ComplianceUnpacking the Balance UnpackingInstalling the Balance Before Use PrecautionsDuring Use Power Supply After UseKey operation Display Symbols and Key OperationDisplay symbols Function TableWeighing Units UnitsCapacity Sample Storing UnitsRE-ZERO Basic Operation Gram Mode WeighingSelecting the counting mode Counting Mode PCSStoring a sample unit mass Counting mode using the Acai function Counting operationStoring the 100% reference mass Percent Mode %Selecting the percent mode Reading the percentageStatistical Calculation Mode Getting StartedMode Selecting the statistical items to outputSelecting the unit PrintOutputting the statistical results Deleting the latest data Clearing the statistical dataReturning to the weighing mode Statistical Calculation Mode Example of UseEnabling the statistical calculation mode Changing the function tableUsing The Statistical Calculation Mode Fast Response AdjustmentOperation MID SlowTerms Calibration ModeCalibration DisplayCalibration Using an External Weight CALEnd Calibration Test Using an External Weight Glp1 Switches Operation Function Switch and InitializationPermit or Inhibit Initializing the Balance Display and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Auto print difference Data output modeAuto print polarity Data outputMode output items TimeoutAK, Error code Factory settingsCondition Cond Hold function Hold Animal weighing modeDescription of the Class Environment, Display CondDisplay refresh rate 5pd Zero tracking trcTrc Decimal point pntDescription of the Item Data Output Mode Standard format Interval output modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format KF format 5if typeMT format CSV format 5if typeData Format Examples Statistical calculation mode apf Capacity indicator apfDescription of the Item Application Function Setting example Comparator FunctionGLP Report Setting the ID NumberID Number and GLP Report Display character setCalibration report using an external weight Calibration test report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT RS-232C Serial Interface Sub 9-pin assignmentsConnection to the AD-8121B Printer Connection to Peripheral EquipmentOFF RsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weight data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking the Balance Performance and Environment TroubleshootingChecking that the balance performs properly Error Codes Asking For Repair Options Page Specifications FX-300iFX-120i / 200i External DimensionsFX-1200i / 2000i TERMS/INDEX GLPCapacity indicator Index Keys and symbols ON/OFF key Sample keyStabilization indicator Condition Counting modeFXi-02 FXi-08 FXi-09 FXi-10 FXi-11 NET indicatorDigit 31, 35 GLP output 23, 25, 26, 32Permit Stability band width Stop bit Stream modeParity Pcs PrinterMemo Memo Memo Page German Scales Office Korea Limited