A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i Data output mode, Auto print polarity

Page 34

Class

Item and Parameter

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Key mode

 

Accepts the

PRINT

key only when

 

 

 

 

 

the display is stable.

 

 

 

 

 

 

 

 

 

 

 

1

Auto print mode A

 

Outputs data when the display is

 

 

 

 

 

(Reference = zero)

 

 

 

 

 

 

 

stable and conditions of ap-p, ap-b

 

 

 

 

 

Auto print mode B

 

 

 

 

 

2

 

and the reference value are met.

 

prt

(Reference = last stable value)

 

 

 

 

 

 

 

 

Data output mode

3

Stream mode

 

Outputs data continuously.

 

 

 

 

 

 

 

 

 

 

 

 

4

Key mode B (Immediately)

 

Accepts the

PRINT

key regardless

 

 

 

 

 

of the display condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accepts the

PRINT

key immediately

 

 

 

 

5

Key mode C (When stable)

 

when the display is stable, or waits

 

 

 

 

 

 

 

for the display to be stable when not.

 

 

 

 

6

Interval output mode

 

Uses interval output mode.

 

 

 

 

0

Plus only

 

Displayed value>Reference

 

 

 

 

 

ap-p

 

1

Minus only

 

Displayed value<Reference

 

 

 

Auto print polarity

 

 

2

Both

 

Regardless of displayed value

 

 

 

 

 

 

ap-b

0

10 digits

 

Difference between reference value

 

1

100 digits

 

 

 

 

 

 

 

 

 

 

 

and displayed value

 

Auto print difference

 

dout

2

1000 digits

 

 

 

 

 

 

 

 

Data output

 

 

 

0

Every measurement

 

 

 

 

 

 

 

 

1

2 seconds

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

5 seconds

 

 

int

3

10 seconds

Interval time for the interval output

Interval time

4

30 seconds

mode

 

(With

prt 6

 

5

1 minute

)

 

 

 

 

6

2 minute

 

 

 

7

5 minute

 

 

 

8

10 minute

 

 

pU5e

 

0

No pause

Selects the data output interval.

 

 

Data output pause

1

Pause (1.6 seconds)

 

 

at-f

 

0

Not used

Selects whether or not automatic

 

 

Auto feed

1

Used

feed is performed.

info

 

0

No output

 

 

 

 

 

 

 

 

1

AD-8121 format

Selects GLP output method.

GLP output

2

General data format

 

 

 

 

 

ar-d

 

0

Not used

Adjusts zero automatically after data

 

 

Zero after output

1

Used

is output

Factory settings. Digit is a unit of minimum weighing value

32

Image 34
Contents RI S WM+PD4001199Page Contents Connection to Peripheral Equipment MaintenanceRS-232C Serial Interface External Dimens IonsAbout This Manual FeaturesIntroduction ComplianceUnpacking the Balance UnpackingInstalling the Balance Before Use PrecautionsDuring Use Power Supply After UseKey operation Display Symbols and Key OperationDisplay symbols Function TableWeighing Units UnitsCapacity Sample Storing UnitsRE-ZERO Basic Operation Gram Mode WeighingSelecting the counting mode Counting Mode PCSStoring a sample unit mass Counting mode using the Acai function Counting operationStoring the 100% reference mass Percent Mode %Selecting the percent mode Reading the percentageStatistical Calculation Mode Getting StartedMode Selecting the statistical items to outputSelecting the unit PrintOutputting the statistical results Deleting the latest data Clearing the statistical dataReturning to the weighing mode Statistical Calculation Mode Example of UseEnabling the statistical calculation mode Changing the function tableUsing The Statistical Calculation Mode Fast Response AdjustmentOperation MID SlowTerms Calibration ModeCalibration DisplayCalibration Using an External Weight CALEnd Calibration Test Using an External Weight Glp1 Switches Operation Function Switch and InitializationPermit or Inhibit Initializing the Balance Display and Keys Function TableStructure and Sequence of the Function Table ExampleDetails of the Function Table Auto print difference Data output modeAuto print polarity Data outputMode output items TimeoutAK, Error code Factory settingsCondition Cond Hold function Hold Animal weighing modeDescription of the Class Environment, Display CondDisplay refresh rate 5pd Zero tracking trcTrc Decimal point pntDescription of the Item Data Output Mode Standard format Interval output modeDescription of the Item Data Format DP Dump print format 5if typeNU numerical format KF format 5if typeMT format CSV format 5if typeData Format Examples Statistical calculation mode apf Capacity indicator apfDescription of the Item Application Function Setting example Comparator FunctionGLP Report Setting the ID NumberID Number and GLP Report Display character setCalibration report using an external weight Calibration test report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT RS-232C Serial Interface Sub 9-pin assignmentsConnection to the AD-8121B Printer Connection to Peripheral EquipmentOFF RsCom Using Windows Communication Tools WinCTConnection to a Computer RsKeyUsing the WinCT software, the balance can do the following Commands to query weight data CommandsCommand List Commands to control the balanceAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking the Balance Performance and Environment TroubleshootingChecking that the balance performs properly Error Codes Asking For Repair Options Page Specifications FX-300iFX-120i / 200i External DimensionsFX-1200i / 2000i TERMS/INDEX GLPCapacity indicator Index Keys and symbols ON/OFF key Sample keyStabilization indicator Condition Counting modeFXi-02 FXi-08 FXi-09 FXi-10 FXi-11 NET indicatorDigit 31, 35 GLP output 23, 25, 26, 32Permit Stability band width Stop bit Stream modeParity Pcs PrinterMemo Memo Memo Page German Scales Office Korea Limited