A&D FX-120i/FX-200i/FX-300i/FX1200i/FX2000i/FX3000i Using The Statistical Calculation Mode

Page 23

5-5-2 Using The Statistical Calculation Mode

1 Press the RE-ZERO key to set the display to zero.

2Place a container on the weighing pan.

Press the PRINT key to cancel the weight (tare). The

balance displays 0.00 g. (Storing the tare value) The tare value data is output when the peripheral output equipment is connected.

3 Weigh formula 1 and press the PRINT key. The balance displays 0.00 g. (Storing the weight value of formula 1)

The weight value data is output when the peripheral output equipment is connected.

4 Weigh formula 2 and press the PRINT key. The balance displays 0.00 g. (Storing the weight value of formula 2)

The weight value data is output when the peripheral output equipment is connected.

5When there are some more formulae to be added, repeat step 4.

6After mixing is complete, press the MODE key to display the statistical results.

7Press the PRINT key to output the number of data saved including the tare value and the total weight.

Output example

21

Image 23
Contents WM+PD4001199 RI SPage Contents External Dimens Ions MaintenanceRS-232C Serial Interface Connection to Peripheral EquipmentCompliance FeaturesIntroduction About This ManualUnpacking Unpacking the BalanceInstalling the Balance During Use PrecautionsBefore Use After Use Power SupplyFunction Table Display Symbols and Key OperationDisplay symbols Key operationUnits Weighing UnitsCapacity RE-ZERO Storing UnitsSample Weighing Basic Operation Gram ModeStoring a sample unit mass Counting Mode PCSSelecting the counting mode Counting operation Counting mode using the Acai functionReading the percentage Percent Mode %Selecting the percent mode Storing the 100% reference massGetting Started Statistical Calculation ModePrint Selecting the statistical items to outputSelecting the unit ModeOutputting the statistical results Clearing the statistical data Deleting the latest dataChanging the function table Statistical Calculation Mode Example of UseEnabling the statistical calculation mode Returning to the weighing modeUsing The Statistical Calculation Mode MID Slow Response AdjustmentOperation FastDisplay Calibration ModeCalibration TermsCAL Calibration Using an External WeightEnd Calibration Test Using an External Weight Glp1 Permit or Inhibit Function Switch and InitializationSwitches Operation Initializing the Balance Example Function TableStructure and Sequence of the Function Table Display and KeysDetails of the Function Table Data output Data output modeAuto print polarity Auto print differenceFactory settings TimeoutAK, Error code Mode output itemsCond Hold function Hold Animal weighing modeDescription of the Class Environment, Display Condition CondDecimal point pnt Zero tracking trcTrc Display refresh rate 5pdDescription of the Item Data Output Mode DP Dump print format 5if type Interval output modeDescription of the Item Data Format Standard formatCSV format 5if type KF format 5if typeMT format NU numerical formatData Format Examples Description of the Item Application Function Capacity indicator apfStatistical calculation mode apf Comparator Function Setting exampleDisplay character set Setting the ID NumberID Number and GLP Report GLP ReportCalibration test report using an external weight Calibration report using an external weightTitle block and end block Underhook PROGRAMMABLE-UNIT Sub 9-pin assignments RS-232C Serial InterfaceOFF Connection to Peripheral EquipmentConnection to the AD-8121B Printer RsKey Using Windows Communication Tools WinCTConnection to a Computer RsComUsing the WinCT software, the balance can do the following Commands to control the balance CommandsCommand List Commands to query weight dataAcknowledge Code and Error Codes Settings Related to RS-232C Maintenance Checking that the balance performs properly TroubleshootingChecking the Balance Performance and Environment Error Codes Asking For Repair Options Page FX-300i SpecificationsFX-1200i / 2000i External DimensionsFX-120i / 200i GLP TERMS/INDEXCondition Counting mode Index Keys and symbols ON/OFF key Sample keyStabilization indicator Capacity indicatorGLP output 23, 25, 26, 32 NET indicatorDigit 31, 35 FXi-02 FXi-08 FXi-09 FXi-10 FXi-11Printer Stability band width Stop bit Stream modeParity Pcs PermitMemo Memo Memo Page Korea Limited German Scales Office